84mm ILLUM Flashcards

1
Q

Describe actions of 84mm ILLUM after expelling charge functions ?

A
  • Priming composition in top of candle ignites
  • Candle & half casings forced onto projectile base, breaking shear screws
  • Candle ejected, half casings fall away
  • Illumination comp ignited
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many pre selected ranges does the 545C have, and what do they range from?

A
  • Seven

- 300-2100m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How many safety arrangements are there in the SAD?

A

Three

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the three safety arrangements in the F555 Fuze?

A
  • Inertia
  • Centrifugal
  • Combined
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the safety wait time for the 545C?

A

60min to allow capacitor to bleed down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How much candlepower in the 84mm ILLUM?

A

650,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Average burn time?

A

30 seconds +/- 5 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the size of the illuminated area from an 84mm illum?

A

400-500m diameter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

at 21 degrees C, what is the time to airburst for the following:

  • 600
  • 1100
  • 1700
A
  • 2.6 +/- 0.25 sec
  • 5.5 +/- 0.3 sec
  • 9.4 +/- 0.35 sec
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the main difference between the 545 and 545C?

A

545C has an electronic fuze

How well did you know this?
1
Not at all
2
3
4
5