8 CCR 1532.1 Cal/OSHA Construction Safety Orders Flashcards

1
Q

Employee exposure without regard to the use of respirators, to an airborne concentration of lead of 30 micrograms per cubic meter of air calculated as an 8 hr TWA

A

Action Level

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Trigger Task I Activities

A

Low Level Exposure (where lead-based paint is present)

  • Manual demolition
  • Manual scraping
  • Manual sanding
  • Heat gun applications
  • Power tool cleaning with dust collection
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Trigger Task II Activities

A

Moderate Level Exposure

  • Lead containing mortar use
  • Lead burning
  • Rivet busting
  • Power tool cleaning without dust collection
  • Cleanup where dry abrasive expendables used
  • Abrasive blasting enclosure movement and removal
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Trigger Task III Activities

A

High Level Exposure

  • Abrasive blasting
  • Welding
  • Cutting
  • Torch burning
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When using a sampling pump, must not exceed a liter loading of _______ total dust

A

ca 2mg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What type of filter is used in a sampling pump?

A

Mixed cellulose ester filter (MCEF), 0.8 micrometer pore size, in cassette filter holder, closed face cassette

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is used to calibrate a sampling pump?

A

Each pump is pre-calibrated with a primary or secondary standard, with a representative sampler in line.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The purpose of calibration is to ensure that _____ matches the ______ set on the sampling pump

A

flow rate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The rotameter response depends on ______, _______ and _______, and must be calibrated on a primary standard.

A

temperature, pressure, and humidity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The sampling pump should run for ____min prior to voltage check and for calibration.

A

5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The same cassette and filter may be used for all calibrations involving the same ______ _______

A

sampling method

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When must sampling pumps be calibrated?

A

Before and after each day.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Calibration steps should be repeated until two readings are within ___%

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly