757 Landing Gear Flashcards
Gear handle ____________ position depressurizes system
Off
NOSE/LEFT/RIGHT annunciators each have one __________ light and one __________ light
AC
DC
DOORS light indicates any gear door is not __________
Closed
GEAR light indicates disagreement between __________ and __________
Handle
Gear
__________ switch overrides gear handle lock solenoid
LOCK-OVRD
Alternate gear extension uses dedicated __________ to release gear unlocks
DC pump (power pack)
__________ are automatically selected with loss of right hydraulic system pressure (shuttle valve)
Alternate brakes
__________ anti-skid is applied in lateral pairs
Alternate brakes
With alternate brakes, __________are inop
Auto brakes
Auto brakes 1 through MAX AUTO based on __________
Rates of deceleration
Max AUTO braking is less effective than___________
Manual Braking
Auto Brakes activate based on __________ and __________
Wheel Spin Up
Thrust Levers Idle
An AUTO BRAKES light indicates that auto brakes are__________ or have been __________
INOP
Disarmed
Auto Brakes deactivate for what five items?
Fault in the system
Speed brake moved towards down position
Off or Disarmed selected
Toe brake
Accumulator gauge Amber band indicates __________
Nitrogen pre-charge
Accumulator Pressure above amber band provides several __________ and provides for ___________ use
Braking Applications
Parking Brake
Parking Brake light indicates ___________ only
Handle position
Brake source light indicates loss of __________ and __________ braking
Normal
Alternate
Reserve brakes switch activates right electric hydraulic pump, regardless of switch position and uses right reserve fluid to power the __________ brake system
Normal
What can be done to raise the landing gear after takeoff if the landing gear lever will not move to the up position?
Push LOCK OVRD then raise handle
Use QRH
What is the meaning of an illuminated landing gear disagree light?
Gear position disagrees with the lever position
Describe how the Alternate Gear Extension System operates
Fluid in the normal supply line is pressurized by a dedicated DC powered electric hydraulic pump to release the gear door and gear uplocks