5's - C7 Flashcards
Rotor start and stop limits

Rotor brake emergency stop
Maximum rotor speed for emergency rotor brake ap- plications, with engines operating, is 76% NR.
Rotor brake routine stop
Engine(s) off,
NR below 40%
150-180 psi applied
not less than 12 seconds
no more than 18 seconds (chapter 2)
Minimum rotor brake pressure for engine start?
450 psi
Maximum rotor brake pressure for engine start?
690 psi
Gust lock limitation, without rotor brake.
a. Dual-engine operation with gust lock engaged is prohibited.
b. Single-engine operation with gust lock engaged will be performed by authorized pilot(s) at IDLE only.
c. Gust lock shall not be disengaged with engine running.
NP limits

NR limits, power ON

NR limits, power off
(autorotation)

NG limits

Torque (Q) limits

Turbine Gas Temperature (TGT)
Limits

ENG Oil Temperature limits

ENG Oil Pressure Limits

XMSN Oil Temp Limits

XMSN Oil Pressure Limits

Fuel Tank indications/limitations

Pneumatic source inlet limitations