45 Questions Always Asked Flashcards

1
Q

What is the Maximum distance of the fire hydrant from the nursing facility?

A

19.311.c

300 Feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How often is a gas pressure test required?

A

19.326.i
Once a Year BY a
person licensed with the State Board of Plumbing Examiners

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How many fire drills must be conducted annually?

A

19.326
12
1 per shift every quarter.
** 3 Shifts * 4 Quarters a year = 12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the minimum sq footage per patient residing in a SEMI-Private room?

A

19.305
80 sq feet

100 sq feet per Pt. in a PRIVATE room

So if two people in a room, room must be 160 sq feet
80*2 = 160

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the MAX Temp for STAPLE food storage in a pantry at the 5 foot level?

A

19.318-k-

85 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Sewerage treatment must be approved by two state entities. what are these TWO ENTITIES?

A

19.322-b/c
1-DADS
2-Texas Natural Resource Conservation Commission.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How often must the SNF’s quality assurance committee meet?

A

19.1917

Quarterly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the MAXimum RECOMMENDED temp for patient use water?

A

19.322
Max:110

Range: 100-110 degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The accounting of the residents trust fund petty cash must be done how often?

A

19.405

Quarterly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How is Blood pressure measured?

A

S/D
Systolic = measures the pressure in the arteries when the heart beats. ** HIGH
over
Diastolic = measures the pressure in the arteries between heartbeats ** LOW

NORMAL 120/80
PRE-Hypertension 120-139 /  80-89
Hypertention1 140-159 / 90-99
Hypertention2  160+/100+
Hypertensive Crisis 180+/110+
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the travel distance allowed from the residents bedroom to the nurses station? Recommended? Max?

A

Recommended: 85 ft
Max: 150 ft
** Can go up to 165 ft if– Built before 8-10-1983

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the Max Number of bed in a WARD?

A

19.305
4
*Both New and Old Facilities

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

In an existing facility, how many inches of Clothes hanging space MUST be available per Resident?

A

19.305
16 Inch

**22 Inch for new Construction, An extra 6 inches!!!

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

In a NEW facility, how many inches of Clothes hanging space MUST be available per Resident?

A

19.334
22 Inch

** 16 Inch for OLD facilities. 6 Inches LESS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How many SQ FEET of RECREATION space PER resident is REQUIRED?

A

19.308 / 19.334-f- / 19.331-d-
An area used for 2 purposes (Living/Dinning Areas) should not be less than 19 Sq Feet

** For any one particular ONE room it should not be any less than 10 Sq Feet per Bed
EX: DINNING ROOM byself should not be less than 100 sq feet if you have 10 beds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the SIZE of a hydrant Service line?

A

19.311-c-
6 inches

** Fire Hydrant must be no less than 300 ft from facility

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What is the REQUIRED Width of a Fire lane ON the property?

A

OLD: Adequate Width
New: 10 Feet Wide (Road) with 2 feet clearance on each side (14 feet)
** Must have 2 Sides of the building with Fire lanes.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is the REQUIRED Width of a Fire lane OFF the property?

A

14 feet wide - 10 roadbed - 2 feet on each side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What is the MAX length of dead end corridors?

20
Q

What are the two criteria which determine window size?

A

19.305
Area of ROOM and Window Sections

**Window must be 8% of the room area (or 16sq feet NEW) AND; Operable window sections may be restricted to not more than 6 nor less than 4 inches

21
Q

What is the MAX height of a bedroom window still?

A

19.305

36 inches

22
Q

How many parking spaces must a facility provide with persons with disabilities?

A

19.319
1

** Must have one parking space regardless of the amount of parking spaces. However, the ratio is 1:25/20 handicap to regular spaces.

  • *New Construction 1:4 parking spaces total
  • *
23
Q

What is the minimum LETTER height for EXIT signs?

24
Q

What is the minimum illumination of exit signs?

A

5 ft candle / 1 ft candle under Aux power

25
What is the MAX distance between smoke doors?
LSC 18.3.7.1 | 200 ft Smoke Barriers
26
What is NORMAL swing direction of bathroom doors?
OUT All door swing into residents room. Exit door must swing out.
27
What is the MAX height of handrails?
19.309 | 36 inches
28
What is the Minimum height of handrails?
19.309 | 33 inches
29
What is the SIZE of the operable SECTION of the window?
19.305 | Operable window sections may be restricted to not more than 6 nor less than 4 inches
30
What is the clearance of the handrail from the wall?
19. 333-f- / 19.342-a-8/9 | 1. 5 inches - 3.5 Inches
31
What is the minimum load bearing capacity of handrails?
19.342 | 250 lbs
32
What is the minimum height of GUARDRAILS? What is the minimum height of GrabBars?
WIKI GUARD RAILS = 42 inches Grab Bars = ADA standard of: 33-36 inches **and SIDE GRAB BARS must be 42 inches long.
33
Grab Bars are required in 3 areas. What are they?
``` 19.319 Toilet / Shower / Tub or SIT Bath *** 1 1/4 - 1 1/2 Thickness 1 1/2 away from wall (clearance) 250 lbs ```
34
What is the MAX height of fire extinguishers?
40+ lbs TOP 3.5 feet above floor Bottom NOT LESS than 4 inches from floor. Below 40 lbs TOP 5 feet above floor
35
How often must fire extinguishers be inspected?
``` 19.315 Keep in mind checked vs inspected. Staff=checked Porfire=inspected STAFF: Once a Month - Check Pin not pulled out ect... General Checks ``` Licensed Agent (Pro Fire): Once a Year . Repairs/ Replacement / Charge / ect.
36
What is the type of handheld fire extinguisher used in the kitchen?
B & C Hood Range in kitchen are fixed and automatic and inspected every 6 months A=Combustible (Wood Types) B=Liquids / (Grease) C=Metal Fire
37
What is the TIME DURATION for EMERGENCY LIGHTS?
1 1/2 hours BAT Power ** More of a generator question 4 Hours for FUEL POWER
38
What is the RATIO of TOILETS to BEDS?
19. 3061-8 | 1: 8
39
What is the RATIO of BATH tubs to residents?
19. 3061 | 1: 20
40
What is the RATE of SHOWERS to RESIDENTS?
19. 3061 | 1: 20
41
What is the RECOMMENDED LAUNDRY and KITCHEN use WASHING temp?
140 degrees 180 Final Rinse for Kitchen
42
What is the required dish sanitizing water temperature?
180 degrees ** SANITIZING same as final RINSE
43
Where are MANUAL fire pull stations located in the facility?
19.314-9- ALL: EXITS / Living Rooms / Dinning Rooms / Nurse Station OR Close to Nurse Station.
44
Emergency power/lighting shall be automatically in operation with ____ after interruption of normal power.
19.303 | 10 Sec
45
Emergency electrical service must be provide illumination for 11 areas. What are these areas?
7) ALARM systems, 1) Means of egress, 6) Exit signs, 4) Dining and living areas, 8) Nurse CALL systems, 2) Nurse stations, 3) Medication rooms, 5) group BATHING areas, 9) TELEPHONE equipment, 10) PAGING or speaker systems, AND 11) ELEVATOR systems if applicable.
46
What is Normal BLOOD PRESSURE?
``` NORMAL 120/80 PRE-Hypertension 120-139 / 80-89 Hypertention1 140-159 / 90-99 Hypertention2 160+/100+ Hypertensive Crisis 180+/110+ ``` * *Systolic +20 each level * * Dystolic +10 each level