3.5 ECCS Flashcards
3.5.1
SITs - Operating
4 SITs Operable
Modes 1-2 and 3-4 >/= 1837 psia
What does an operable SIT mean?
Pressure 600 psig - 625 psig
2300-4400 ppm boron
Motor operated isolation valve fully open, power removed
Volume of 28%-72% NR or 1802-1914 cubic feet of borated water
3.5.2
SITs shutdown
4 SITs operable with volume 39% WR - 83% WR
OR
3 SITs operable with volume 60% WR - 83%WR
Modes 3-4 (>/= 1837 psia)
3.5.3
ECCS - Operating
Two trains Operable
Modes 1-2 and 3 w/ Ppzr >/= 1837psia and Tc >/= 485F
What makes up an ECCS train in Modes 1-3?
HPSI subsystem and LPSI subsystem
3.5.4
ECCS - Shutdown
One HPSI train operable
Mode 3 less than 1837 and 485F
Mode 4
3.5.5
RWT shall be operable Modes 1-4 Must meet level requirements Boron concentration of 4000-4400 ppm Tank not isolated Temp between 60F and 120F
What is RWT level requirement dependent on?
RCS Temperature. There’s a table in the Tech Spec Basis.
3.5.6
TSP baskets have 524 cubic ft of active TSP
Modes 1-3