34 KO CURTAIN Flashcards
The KO Curtain will ONLY be deployed on orders of the
Officer of the FIRST ARRIVING LADDER COMPANY and/or the IC
Testing conducted by FDNY and NIST showed an immediate
50% decrease in temperatures and significant flame reduction when the KO Curtain is deployed. However there will be an increase
In the smoke condition
KO curtain can be deployed from
2 floors above the fire if needed
The deployment FF MUST have their
Facepiece on in case of an auto exposure
The KO Curtain shall NEVER be deployed in a
Horizontal position
The 1st arriving ladder officer will coordinate the
Deployment of the KO curtain
Allow the KO curtain to drop
DO NOT THROW
When assured that the target window is completely covered the deploying and receiving FF’s will
Maintain control of their respective ropes. The ropes shall NOT be tied off. The deployment window will be closed to prevent auto exposure
If the KO Curtain will be subject to direct flame exposure for an extended period of time the IC should consider
Deploying a 2nd KO Curtain OR Window Fire Blanket to cover the 1st one
Both the deploying FF and the receiving FF will
Remain in position until otherwise ordered by the IC
The removal of the KO curtain must be
Approved by the IC. The request for the removal of the KO Curtain will be made by the ladder company officer inside the fire apartment after first consulting with the engine company officer in charge of the hose line inside the apartment. The ladder company officer shall use the TIC to confirm all fire has been extinguished. The engine officer shall insure that the nozzle team is aware of the KO Curtain removal