300 SERIES Flashcards

0
Q

WHEN SHOULD COMPNY OFFICERS INCLUDE REMAINING AIR SUPPLY?

303.02

A

PCAN REPORTS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

WHT ARE THE 5 KEY ASPECTS OF AIR MANAGEMENT?

303.02

A
  1. FULL CYCLINDER
  2. KNOW THW AMOUNT OF AIR IN CYCLINDER
  3. SELF AWARENESS
  4. PSYCHOLOGICAL CONTROL
  5. STRONG KNOWLEDGE OF SCBA
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

HOW DO YOU GAIN SELF AWARENESS AS IT PERTAINS TO AIR MANAGEMENT?

303.02

A

BREATH DOWN EXERCISES

KNOWING HOW LONG IT TAKES TO BREATH DOWN A BOTTLE.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

HOW MUCH CUBIC FOOT OF AIR IS IN A SCBA TANK?

303.03

A

66 CUBIC FEET

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

HOW OFTEN SHOULD SCBA BOTTLES BE TESTED?

303.03

A

EVERY 5 YEARS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

WHAT IS THE NIOSH RATTING OF A 45 MINUTE BOTTLE CALLED?

303.03

A

SERVICE LIFE

PERFORMED BY A MACHINE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

WHAT 7 FACTORS CONTRIBUTE TO THE LONGEVITY OF AIR SUPPLY?

303.03

A
  1. ACTIVITY
  2. PHYSICAL CONDITION
  3. PHYSICAL SIZE
  4. EMOTIONAL FACTORS
  5. TRAINING
  6. FULLY CHARGED CYCLINDER
  7. LOOSE/IMPROPER FACE PIECE
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

WHAT ARE THE PARTS OF THE (SCBA) CYLINDER VALVE ASSEMBLY?

303.03

A
PRESSURE GUAGE
QUICK RELEASE FITTING
FILL PORT
BUMPER
HAND WHEEL VALVE
SAFETY RELIEF
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

WHAT IS THE VALVE ASSEMBLY MADE OF?

303.03

A

FORGED ALLUMINUM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

WHAT ARE THE COMPONENTS OF THE BACK FRAME HARNESS ASSEMBLY?

303.03

A
QUICK DISCONNECT
REGULATOR 
BATTERY COMPARTMENT
PASS SENSOR MODULE
RIC U.A.C.
RETENTION STRAP AND CYLINDER LATCH
PRESSURE REDUCER
SNAP CHANGE MECHANISIM
E.B.S.S.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

WHAT DOES THE BACK FRAME PRESURE REDUCER DO?

303.03

A

REDUCE THE BOTTLE PRESSURE TO 110-160PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

HOW DO YOU KNOW THE SCBA SECONDARY AIR PATH HAS BEEN ACTIVATED?

303.03

A

VIBRALERT GOES OFF

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

WHERE IS THE RIC U.A.C. LOCATED?

303.03

A

LEFT SIDE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

WHERE IS THE E.B.S.S. SYSTEM LOCATED?

303.03

A

RIGHT SIDE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

HOW LONG IS THE E.B.S.S. HOSE?

303.03

A

3 FEET

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

WHERE IS THE CONTROL CONSOLE LOCATED?

303.03

A

RIGHT SHOULDER STRAP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

THE PRESSURE REGULATOR MAINTAINS POSITIVE PRESSURE UP TO WHAT FLOWS?

303.03

A

500 LPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

THE HEADS UP DISPLAY SHOWS WHAT?

303.03

A

AIR SUPPLY AND BATTERY INDICATOR

18
Q

WHEN DOES THE AIR SAVER SWITCH DEACTIVATE?

303.03

A

WHEN THE WEARER INHALES WITH A PROPER FACE SEAL.

19
Q

WHERE IS THE RED PURGE VALVE LOCATED ON THE REGULATOR?

303.03

20
Q

WHERE IS THE QUICK DISCONNECT FITTING LOCATED?

303.03

A

18 INCHES FROM REGULATOR

21
Q

WHAT IS THE DIFFERENCE IN AIR RESISTANCE IN THE EASY FLOW 1&2 REGULATORS?
303.03

22
Q

HOW MANY SIZES OF FACE PIECES AND NOSE CUP SIZES IS THERE IN THE SCBA MASK?

303.03

23
Q

HOW LONG WILL ALL 5 LIGHTS OF THE SCBA HEADS UP DISPLAY STAY LIT FOR WHEN IT IS TURNED ON?

303.04

A

20 SECONDS

24
WHEN INSPECTING THE SCBA CYLINDER WHAT DO YOU LOOK FOR? 303.04
DENTS GOUGES UNWRAPPING OF COMPOSITE HYDRO STAT DATE
25
WHEN DOES THE PASS PRE ALARM ACTIVATE? 303.04
AFTER 20 SECONDS
26
WHEN DOES THE PASS DEVICE FULL ALARM ACTIVATE? 303.04
AFTER 30 SECONDS MOTIONLESS
27
APPROXIMATELY HOW MANY TURNS DOES IT TAKE TO TURN ON SCBA? 303.05
2 1/2 TURNS
28
HOW MANY BATTERIES DOES THE PASS DEVICE TAKE? 303.05
3 C CELLS
29
WHAT COLOR LIGHT IS PRESENT ON SCBA CONSOLE WHEN BATTERIES ARE GOOD/BAD? 303.06
GREEN/RED
30
HOW DO YOU PREVENT RADIO FREQUENCY INTERFERENCE (RFI) ON THE PASS DEVICE? 303.06
KEEP AL LEAST 6 INCHES FROM PORTABLE RADIO.
31
HOW MANY LIGHTS ON THE HEADS UP DISPLAY AND WHAT DO THEY REPRESENT? 303.07
4 RECTANGULAR FOR AIR SUPPLY | 1 ROUND FOR BATTERY
32
WHAT DO THE SCBA H.U.D LIGHTS REPRESENT? 303.07
2 GREEN FULL 1 GREEN 3/4 YELLOW 1/2 RED 1/4
33
HOW DO YOU KNOW PASS DEVICE NEEDS BATTERIES? 303.07
20 SECONDS OF ROUND RED LIGHT FOLLOWED BY BLNIK OF RED LIGHT ONCE A SECOND
34
WHAT TYPE OF C BATTERIES DO YOU USE FOR THE PASS DEVICE? 303.08
ALKALINE
35
WHAT DO YOU DO IF THE TONES DO NOT ACTIVATE WHEN CHANGING THE SCBA BOTTLE? 303.09
CHANGE BATTERIES
36
HOW MANY PUMPS OF MULTI WASH MINI IS SPRAYED INTO REGULATOR? 303.10
AT LEAST 6
37
HOW MANY SPRAYS FOR FACE PIECE AND FOR HOW LONG 303.10
3 INSIDE 3 OUTSIDE LET STAND 10 MINUTES
38
WHEN TAGGING AN ITEM WHAT INFO DO YOU INCLUDE? 303.12
NAME, STATION,SHIFT, REASON
39
WHAT SHOULD YOU DO IF AIR BEGINS TO FLOW FREELY INTO FACE PIECE? 303.13
OPEN PURGE VALVE AND GATE DOWN BOTTLE TO MEET DEMAND OF USER.....EXIT!
40
HOW DOES THE EBSS SYSTEM WORK? 303.13
VIBRALERT WILL ACTIVATE ON BOTH UNITS IF AIR IS LOW IN EITHER BOTTLE. WILL USE LEAST PRESSURE FIRST.
41
HOW MUCH PRESSURE CAN BE EMITTED FROM EBSS FEMALE COUPLING IF ACTUATED? 303.13
160 PSI
42
AT WHAT PRESSURE DOES THE SCBA AIR COMPRESSOR GO INTO COOL AND PURGE MODE? 303.14
5500 PSI