The vertical distance from a fixture outlet to the trap weir should not be more than _______ inches.
24 inches
The vertical clearance from open electric service conductors should be at least _____ feet over residential properties.
8ft
In homes located in areas having a history of ice forming along the eaves, an ice barrier consisting of at least __________ layers of underlayment cemented together is required.
3 layers
Masonry chimneys should extend at least ____ feet higher than any portion of a building within 10 horizontal feet.
2ft
The horizontal distance from the fixture outlet to the trap weir should not be greater than _______ inches measured from the centerline of the fixture outlet to the centerline of the inlet of the trap.
30
Open electrical service conductors that are not installed in a raceway or provided with a jacket should have a clearance of at least ____ from the sides of doors, decks, stairs, ladders, and balconies, and from the sides and bottoms of openable windows.
3ft
The vertical clearance of the service drop should be at least _____ feet above the grounds of a residential property.
12ft
In general, each plumbing fixture should be separately trapped by a _____________.
Your Answer:
liquid seal trap
If the service or feeder rating in amps is 200, then the aluminum AWG size should be _______.
4/0