205E - Cranking System Testing & Service Flashcards
What is the first component of the cranking system that must be tested?
The battery group.
Isolate the batteries when testing.
205E pg. 2
If the hydrometer on a maintenance free battery is dark, what should be done before testing the battery?
Charge the battery at 15-25Amps for 15 minutes.
205E pg. 3
How should a surface charge be drawn off a battery?
Carbon pile and draw 300Amps for 15 seconds.
205E pg. 4
How should a battery capacity test be performed?
Draw 1/2 rated CCA for 15 seconds. Voltage should not drop below 9.6V at 21 degrees C.
205E pg. 4
If the specific gravity readings of the battery’s cells differ by more than ______, the battery must be replaced.
0.050 points
205E pg. 5
If a blue haze appears from any cell while loading a battery, what does this indicate?
A shorted cell. Replace the battery.
205E pg. 5
When testing cranking motor current draw, what could cause a higher than spec current draw with a slower cranking speed?
- Increased friction in engine (cold temperatures)
- High viscosity oil
- Mechanical binding in engine
- Lack of cranking motor bushing lubrication
- Armature rubbing on pole shoes
- Internal shorts or ground faults
205E pg. 7
What is the acceptable voltage drop across the starter solenoid contact disc?
0.2V
205E pg. 8
When using a carbon pile to load the starting system cables in a 12V system, what voltage drop is acceptable?
12V system: 0.5V drop max
24V system: 1V drop max
205E pg. 10
In a 24V system, what amperage would you load the starting system cables to when checking for a voltage drop in the cable set?
24V System: Load to 250A
12V System: Load to 500A
205E pg. 9
If there are two battery locations or if the system has two sets of cables running to the starter, how would the cables be tested for voltage drop?
Each location’s battery cable set must be tested separately.
Current flow is shared equally by each battery cable set.
12V System: Load carbon pile to 250A (instead of 500A). Max 0.5V drop
24V System: Load carbon pile to 125A (instead of 250A). Max 1V drop
205E pg. 10
What is the maximum acceptable voltage drop across the starter magnetic switch coil?
Carbon pile set to 100A (60A on 24V system)
Max 0.2V drop
205E pg. 13
What is the maximum acceptable voltage drop across the starter magnetic switch conductors?
Carbon pile set to 100A (60A on 24V system)
Max 0.2V drop across each conductor.
Max 0.5V drop across both conductors and coil together.
205E pg. 13
Before removing the starter and when checking if the engine is able to freely rotate, how many revolutions should the engine be manually rotated?
At least 2 revolutions.
205E pg. 19
With the cranking motor removed, if the ring gear is found to be damaged, what other component is also likely damaged?
Cranking motor pinon gear.
205E pg. 19