19. Performance Testing Flashcards
Notes
10,000 lbs - 25 ft stop
+10,000- 35 ft stop
Combination + 10,000- 49 ft stop
Vacuum test- 22 inch Hg
Readings should be taken min 5x
Parking brake at 20%
Hale Products Pump Test Pit Design
Don’t use float type suction in test
Parallel for pump test
__ testing is preferred to load testing, because it does not stress the battery.
Conductivity testing
If the voltage drop exceeds __ volt, the test is considered to have failed
0.3 volts
Performance testing for CAFS max airflow at ___ psi for __ mins
125 psi for 20 mins
__ __ Should be tested in each receptacle
Duplex receptacles
The total continuous electrical load test is normally conducted during the ___ and ___ test
Solenoids and relay test
The test gauges should themselves be regularly tested and calibrated within __ days prior to the test for accuracy
60 days
Any gauge that is off by more then ___ psi must be recalibrated, repaired, or replaced
10 psi
For pumps that operate at less than 1500 gpm, the priming device should vacuum in __ sec to lift water __ ft through __ ft
30 sec
10 ft
20 ft
A complete set of readings min of __ times during the 20 min test for 100 % capacity
5x