13. Relay Pump Operations Flashcards
To establish any type of relay You will need at least __ fire pumpers hose lines and personnel
2
One fire pumper is located at a water source it is called the __ pumper
Source pumper
___ pumper is the most important pumper in a relay because it is located at a water source it supplies the water to the entire incident
Source
Should be the largest fire pump
Fire pumper is located at the fire scene serves as the workhorse at the incident
Attack pumper
___ psi per 100 ft when flowing 1000 gpm in a 5 inch hoseline
7 psi
A good rule of thumb is that if the discharge pressure will exceed __ psi for LDH or ___ psi for a medium size hose, a relay pumper is needed to boost the water pressure
80 psi
175 psi
Ideally no relay operation should extend for more than __ feet
800 ft
You should add ___ psi for residual pressure to prevent cavitation
20
The most common type of relay, as it uses actual flow calculations to determine the quantity of water required
Calculated flow relay
Standardize the supply pressures based on prior experience for relay pumping operations
Constant pressure relays
Notes
Goal is to maintain 20 psi of residual pressure
Check valve in tank to pump
When shutting down the relay pumping operation, the __ pumper acts first
Attack
A __ valve let a pumper connect into the relay without shutting down the entire relay operation
Relay valve