19. Fire protection✅ Flashcards

1
Q

Where are the engine fire loops install?

A

Pylon nacelle
Engine core
Fan section

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What happens of both fire loops fail simultaneously?

A

Fire warning will be issued if the failure occurs within five seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What does the amber DISCH light mean?

A

Bottle has lost its pressure either by a fault or pilot selection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How many fire bottles are provided for each engine?

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is accomplished when the engine fire push button is pushed?

Make an acronym❌
SA CCCCC D

A
Silences aural warning
Arms Squibs
Closes: hydraulic fire, low pressure fuel valve, engine bleed, pack flow Valves
Cuts power to Fadec
Deactivates IDG
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is accomplished when the engine fire test button is pressed?❌

CME SEF

A
CRC, 
Master warning lights, 
Engine fire button red 
Squib disch charge lights illuminate 
ECAM fire warning, 
Fire light on ENG panel
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What should occur if the APU is operating an APU fire is detected?

A

On the ground: the APU emergency shut down and bottle discharge

In the air: no automatic functions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly