100-135 Flashcards
TB104 Urban Search and Rescue
NFPA 1670 -
NFPA Standard on Operations and training for technical rescue incidents.
TB104 Urban Search and Rescue
Who is responsible for the completion of the “permit entry”
Rescue group supervisor
*usually C11
TB104 Urban Search and Rescue
Non user companies may staff which crews on technical rescue incident. X3
Rigging crew, cutting crew, and ventilation
TB104 Urban Search and Rescue
There is a user task force in each division located at fs x6
3, 5, 27, 85, 88, 89
TB104 Urban Search and Rescue
The primary control method for atmospheric hazards is ____
Ventilation
TB104 Urban Search and Rescue
SAR: Supplied Air Respirators involve a separate air supply manifold, which is maintained by a Breathing Air Supply Monitor outside of the confined space. The rescuer is connected by air hose, up to a maximum of_____feet in length, to the air manifold
300ft
TB104 Urban Search and Rescue
All rescuers using supplied air shall wear an escape bottle, that shall normally be ____minutes of additional air to be used for emergency exit involving rescuers only.
10 min
TB104 Urban Search and Rescue
A copy of the confined space Rescue entry permits shall be forwarded to the department safety office and retained for ___ years from date of incident
5 years
TB 106 LCES
LLCCESS
Lookouts/location
Communication/conditions
Escape routes
Safety zones/ safety equipment
TB 106 LCES
Communication among members at an incident is always best when accomplished ____
Face to face
TB 106 LCES
Sounding the horn for ___ sec followed by ___ sec of silence and repeating this cycle ___ times for a total of ____ sec indicates that all companies need to retreat to their safe area.
10 &10sec
3 times
50sec total
TB 111 Elevator kit
Warning: when picking any elevator hoist way door , always _____
Shutdown power at mainline disconnect
TB 111 Elevator kit
Klein screwdriver with ___” tip and ____ 8”shank
3/8” tip and 8” shank
TB 111 Elevator kit
The pick up rollers are usually located within ___ to____from the leading edge of the door
8 to 12”
TB 111 Elevator kit
Kone equipment can sometimes be identified by their trademark, “_________”
Hall lantern
TB 111 Elevator kit
The pick may enter the interlock box which has up to ____volts AC when energized, and further emphasizes why the power must be shut down
230 volts
TB 111 Elevator kit
ThyssenKrupp pick
Typically there is a small slot in the plate which is located approximately ___ to ___ “ from the leading edge of the door.
3 to 4 “
TB 111 Elevator kit
When using the paddle, insert it through the door approximately ___ to ___ “ up from bottom of the door
6 to 12”
TB 111 Elevator kit
Which poling technique is most dangerous
Poling up
TB 111 Elevator kit
If the car floor is greater than ____feet above or below the landing it may be necessary to use alternate evacuation procedures or a rooftop exit.
3 ft
TB 111 Elevator kit
Step stool!
The lightweight foldable step stool is sturdy enough to support rescuers and may hold up to _____lbs
300lbs
TB 111 Elevator kit
Cleaning
Mix ___ tablespoons of mild laundry detergent or non antibacterial dish soap in spray bottle.
2 tablespoons
TB 111 Elevator kit
For replacement of non inventory item such as tags , ERK wedges or picks, send an email to LAFD._________@lacity.org
LAFD.elevatorrescue@lacity.org
Tb 113 Introducing the alameda corridor
In the mid Corridor section trains will descend into a 10 mile long( ____’ deep x ____’ wide)
33’ deep x 51’ wide
Tb 113 Introducing the alameda corridor
Each division, battalion and fire company will be issued a knox box key to access the alameda corridor. Each key can be identified by the engraved description “____”
ACTA
Tb 113 Introducing the alameda corridor
_____ will be located at each access gate to identify retractable ladder.
____ will be located at each standpipe connection
2 green Botz dots = access gate with retractable ladder
1 green Botz dot = standpipe connection
Tb 113 Introducing the alameda corridor
46 retractable ladders are located along the mid corridor trench, one every ____ ft
1000ft
Tb 113 Introducing the alameda corridor
It takes approximately ___to ___ to lower a ladder
1 to 1 1/2 min
Tb 113 Introducing the alameda corridor
If a ladder is lowered it will trigger alarm to a dispatch operator at the alameda corridor dispatch center who will direct all trains to slow to ____ mph
- what is average speed in the corridor
10mph
Average speed= 40mph
Tb 113 Introducing the alameda corridor
Emergency telephones are located at each ______ at the top and bottom of trenche
Retractable ladder
Tb 113 Introducing the alameda corridor
Pump stations
There are ___ pump stations located within the corridor
2
Tb 113 Introducing the alameda corridor
Dry standpipes are located every ___ ft
500’
TB 116 Metro heavy rail lines
The train configuration with a 2 car minimum, which included one A car and one B car and up to ___ cars maximum
6
TB 116 Metro heavy rail lines
Train car dimensions?
Length-
Wide-
High-
75’ long
10’ wide
12’ height
TB 116 Metro heavy rail lines
Train car weight
80,000lbs
TB 116 Metro heavy rail lines
MAx speed
70mph ( 55mph from union station to Westlake
TB 116 Metro heavy rail lines
The trains are propelled by ____ traction motors per car
4
TB 116 Metro heavy rail lines
Each trains power is supplied by contact rail. How many volts supplied?
750 volts DC
TB 116 Metro heavy rail lines
Where are batteries located
Volts they provide
Under the B car
37.5 volts DC
TB 116 Metro heavy rail lines
Max passengers in “crush load”
220
TB 116 Metro heavy rail lines
After operating external emergency door handle wait ___ seconds then manually separate doors
*which doors will this operate
5 sec
- only center doors