1 Flashcards
What covers Damage Mechanisms Affecting Fixed Equipment in the Refining Industry?
1 RP 578
2 RP 576
3 RP 571
4 Publ 581
RP 571
What covers Inspection of Pressure Vessels?
RP 571
RP 578
RP 572
RP 576
RP 572
What covers Inspection of Pressure-Relieving Devices
RP 571
RP 578
RP 572
RP 576
RP 576
What covers Welding Inspection and Metallurgy?
RP 571
RP 577
RP 572
RP 576
RP 577
What covers Material Verification Program for New and Existing Alloy Piping Systems?
RP 571
RP 578
RP 572
RP 576
RP 578
What covers Fitness-For-Service?
RP 579
RP 578
RP 572
RP 576
RP 579
What covers Risk-Based Inspection?
RP 571
RP 580
RP 572
RP 576
RP 580
What covers Risk-Based Inspection - Base Resource Document?
RP 571
Publ 581
Publ 2201
RP 576
Publ 581
What covers Procedures for Welding or Hot Tapping on Equipment in Service?
RP 571
Publ 581
Publ 2201
RP 576
Publ 2201
The _______________ is responsible to the Owner/user for activities involving design, analysis or evaluation of pressure vessels and pressure-relieving devices covered by this inspection code.
Engineer
The Inspector or Engineer
Corrosion Specialist
Owner
Engineer
The _______________ shall maintain certification records of the examiners employed, including dates and results of personnel qualifications.
Engineer
The Inspector or Engineer
Corrosion Specialist
Owner
Examiner’s Employer
The Inspection Plan should be developed by
The Inspector
The Engineer
The Inspector or Engineer
The Inspector and Engineer
Engineer
The Inspector or Engineer
Corrosion Specialist
Owner
The Inspector or Engineer
Who shall be consulted when needed to clarify potential damage mechanisms and specific locations where they may occur?
Engineer
The Inspector or Engineer
Corrosion Specialist
Owner
Corrosion Specialist
When RBI assessments are used to set vessel inspection intervals, the assessment shall be updated after _______________.
Each Vessel Inspection
Who should the Inspector consult to determine when it is necessary to remove deposits or linings to perform adequate inspections.
Engineer
The Inspector or Engineer
Corrosion Specialist
Owner
Corrosion Specialist
Temperature range Carbon and Low Alloy Steels are susceptible to CUI.
10 F and 350 F
0 F and 350 F
140 F and 350 F
140 F and 4000 F
10 F and 350 F
Temperature range Austenitic Stainless Steels are susceptible to CUI.
10 F and 350 F
0 F and 350 F
140 F and 350 F
140 F and 4000 F
140 F and 400 F
With Austenitic Stainless Settls, CUI usually is in the form of _______________.
Stress Corrosion Cracking
Type 300 series stainless steel should be conducted with potable water or steam condensate having a chloride concentration of _______________.
Less than 50 ppm
At ambient temperatures, carbon, low-alloy and other ferritic steels may be susceptible to __________ failure.
Brittle
Crack
HICC
SCC
Brittle
To minimize the risk of brittle fracture during a pressure test, the metal temperature should be maintained at least __________ degrees F above the MDMT for vessels that are more than 2” thick.
10
20
30
40
30
Crack-like flaws and environmental cracking in welds shall be assessed by _______________.
Engineer
The Inspector or Engineer
Corrosion Specialist
Owner
Engineer
Preferential weld corrosion shall be assessed by _______________.
Engineer
The Inspector or Engineer
Corrosion Specialist
Owner
Inspector
If re-pumping a flanged joint is contemplated, afftected fasteners should be __________ first.
Engineer
The Inspector or Engineer
Corrosion Specialist
Owner
Renewed