Structural metal studs can be used for buildings up to 5 storeys. T or F
T
Loadbearing metal framing components are made of hot dipped galvanized steel in which gauges?
20, 18, 16 and 14
Non-loadbearing framing systems are made of ___, ____ and ____ gauge galvanized steel.
25, 22 and 20
Runners should be the same gauge as the steel studs (or heavier). T or F
T
Flanges for sheet steel stud wall framing should have flanges be at least ____.
30 mm (1-3/16”)
Any runners must be attached to the building at approx. ____ from their ends and at _____ o.c spacing for interior walls or ____ for exterior walls.
50 mm, 24”, 12”
Which explosive actuated too fastener us suitable for anchoring a pin in a concrete ceiling for hanging a suspended ceiling?
Eye pins
What are two wall anchors used to hold a metal door frame in a concrete block wall?
Wire mason anchors and metal strip masonry anchors.
What are hold-down clips used for?
To hold fire-rated ceiling tile in place.
How much clearance is require for placement of ceiling tiles?
Leave clearance for recessed lights, ducts, and other features and a minimum of 150 mm (6”) clearance between the old and new ceilings if you are dropping a ceiling.
Make sure there is a minimum of 50 mm clearance from any pipes, wires and other objects that could interfere with placement of the Ceiling tile.
What can be used to temporarily hold ceiling components together before fastening?
Ceiling track clips
Steel door frames that are part of a block wall are kept from bowing or twisting by using what?
Using internal spreaders the size of the door plus clearances.
Where is the chalk line reference required for ceiling tile wall mouldings?
The chalk line is snapped at the top of the wall moulding so not visible
What supports the main tees?
Hanger wires which are suspended from eye tees
What is the length required for border tees in a grid ceiling system?
The length of the border tee will equal the measurement from the last tee to the wall angle minus 3 mm for the wall angle thickness.