For posterior CAD/CAM crown preps, what is the ideal occlusal reduction
1.5-2.0 mm
What is the margin design for a posterior CAD/CAM crown
1 mm Heavy chamfer, shoulder, or butt joint
How much taper is on a posterior cad/cam crown ideally
6-10 degrees
cad/cam anterior full crown prep facial and lingual reduction
1.0-1.5 mm
cad/cam anterior crown incisal reduction
1-2 mm
cad/cam anterior crown reduction at the margin
1 mm
cad/cam anterior crown taper
6-10 degrees
What type of margin do you want on an anterior cad/cam crown
chamfer or shoulder
How many planes of reduction should a cad/cam anterior crown have
3
What is an inlay
it is similar to a filling that fits inside cusp tips at the center of the tooth’s surface
how does an onlay differ from an inlay
it is more extensive and extends over at least one cusp….or the entire biting surface of the treated tooth
Why should the margins have sharp edges for a cad/cam onlay?
so they are easily identifiable
what is the minimum occlusal reduction for a cad/cam onlay
1.5 mm
what is the angle of the internal axial walls in a cad/cam onlay
6-10 degrees
How much interproximal flare is used for a cad/cam onlay
100-120 degrees