Wyndham deck Flashcards

1
Q

Regular Business Hours?

A

24 Hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Building population regular business hours

A

270

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Building population non regular business hours

A

230

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Assembly areas outside building

A

Hester park, Manhattan bridge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Assembly areas inside building (SC level)

A

Fitness center, meeting room

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Assembly areas inside building (C level)

A

Restaurant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Assembly areas inside building(1st floor)

A

Lobby

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Assembly areas inside building(17)

A

Meeting Room

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Assembly areas inside building (18)

A

Lounge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How many stories above street level

A

18

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How many stories below street level

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How many setback levels

A

5, (2, 7, 15, 17, 19)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How many EXIT stairways

A

4, (A, B, C, D)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Access stairway A

A

SC, C, 1-19 Mechanical room

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Access stairway B

A

Cellar, 2nd floor-roof

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Access stairway C

A

Cellar to 1 floor st

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Access stairway D

A

SC to 1st floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Pressure Stairs

A

Non (open balcony and get to another building’s)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Reentry floors

A

All floors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Fire tower

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Access stair any continence stair between floors

A

Non

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Roof access by stairwell?

A

Stair B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Letter destination for elevator bank?

A

A, E, F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Elevator car 1

A

Subcellar to 19th floor mechanical room (A)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

Elevator car 3 ADA

A

Sub cellar to 1 Floor (E)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

Elevator car 4 Freight

A

Cellar to 1 Floor St (F)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

HVAC Zone?

A

2nd floor to 16 floor

28
Q

Where is HVAC supply fan located?

A

19 floor, through floor ducting

29
Q

Does 18 have a supply fan?

A

Yes, in 19 floor mechanical room

30
Q

What kind of heating system?

A

Central

31
Q

What kind of AC system?

A

Central

32
Q

Is there a mechanical room on 20?

A

Yes

33
Q

What kind of supply for the mechanical room

A

Gas

34
Q

Where is natural gas shut off located?

A

Cellar in Gas meter room

35
Q

Emergency backup?

A

Yes, Generator

36
Q

How many gallons of fuel capacity in the generator?

A

125 gallons

37
Q

Where is the tank located for the generator?

A

under the generator

38
Q

Where is the generator?

A

19 floor roof mount on west side of the building, next to stair A

39
Q

Any other generator tank?

A

Refill tank at 19 floor in isolate room

40
Q

How many gallons does the extra generator tank hold?

A

55 gallons

41
Q

Any UPS or Battery backup system?

A

None

42
Q

Where is supply fan located?

A

on roof

43
Q

What floor is supply fan service?

A

Every floor

44
Q

Where is the service access to serve stand pipe?

A

Stair A to 17, B for above

45
Q

Where is fire pump located?

A

SC

46
Q

System purge capability

A

Smoke purge

47
Q

How often does this building run fire drills?

A

Every 3 months on each shift

48
Q

Any special needs for this building

A

Handicapped list at lobby for fire department

49
Q

Where is the water supply for standpipe unit from?

A

From city main

50
Q

Where is the main control valve for the standpipe?

A

Next to the fire room

51
Q

Where is the standard riser?

A

Stairwell A from SB to 17, stairwell B from 17 to roof

52
Q

Where is the isolation valve for stand pipe system

A

7th floor

53
Q

Where is the fire pump

A

Fire pump room, SB level

54
Q

Where is the fire department connection?

A

Hester and Bowery corner

55
Q

Is it a combination system?

A

Yes, painted yellow

56
Q

What is the combination system

A

Consists both of sprinkler piping and a standpipe for the building

57
Q

What type of sprinkler system in the building

A

Wet sprinkler system

58
Q

What is the primary water source for the sprinkler?

A

City main

59
Q

Where is the main shutoff valve?

A

Fire room

60
Q

Where is the shutoff valve for each floor?

A

Stairwell

61
Q

What kind of portable extinguishers are in the building?

A

ABC

62
Q

Fire alarm panel?

A

Yes

62
Q

Any special extinguishers?

A

Restaurant has 10 years pressure tank, non water fire extinguisher, ANSUL system, caller restaurant

63
Q

Where are the portable fire extinguishers?

A

Every floor hallway and mechanical rooms

64
Q

Any problem assembly area?

A

Restaurant