Written Flashcards
List 5 of the 7 factors that affect the duration of air in your SCBA, according to the Equipment and Procedures manual.
Degree of training/experience Degree of user's conditioning Type of work being performed Condition of the SCBA Whether SCBA was fully charged Emotional factors Loose/improperly fitting facepiece
List 4 of the 6 subassemblies that make up the SCOTT, according to the E & P. (CPR BFF)
Cylinder/valve assembly
Pressure reducer/high pressure hose assembly
Remote gaugeline assembly
Backframe/harness assembly
Facepiece mounted regulator/low pressure hose assembly
Facepiece assembly
Name the two dates related to the SCBA cylinders recorded during monthly inspections.
Last hydrostatic test
In-service date
How often are cylinders hydrostatically tested?
Every 5 years
What is the max service life of a cylinder?
15 years
According to the E & M manual, 1 3/4” hose is tested annually at ___ PSI for ___ minutes.
300, 5
5” hose is tested annually at ___ PSI.
200
A 100’ section of 5” hose has 3 markings on it. What are these markings and where can they be found?
Single white stripe at 25’ and 75’
Double white stripe at 50’
Constant Gallonage Nozzle
Will flow constant amount of water regardless of stream shape
Does so through a selector ring that increases/decreases size of discharge orifice
Automatic (Variable) Gallonage
Increase in pressure increases orifice size, allowing more volume (deflector moves out as pressure is increased)
Smooth Bore Nozzle
Fixed orifice and single pattern
According to IFSTA, a fire stream is identified by its size and type. Size refers to ___ and type refers to ___.
Volume (GPM), pattern/shape
List 2 ways to reduce friction loss. (SIRUM)
Shorten hose lay Increase hose diameter Reduce kinks Use smaller tip More lines
The tip of a smooth bore nozzle should be no larger than:
1/2 the diameter of the hose
Ladder weight limits:
Folding - ___ lbs.
Straight/roof - ___ lbs.
Extension - ___ lbs.
300
750
750
When moving or removing a ladder that was previously placed by someone else, it is first necessary to:
Coordinate with those who originally placed the ladder.
A ladder with a working height of 16’ should be ___’ away from the wall at the bottom.
4
Name 3 locations to avoid when placing ladders, according to the E & P manual. (HOBI)
Horizontal openings
Overhead obstacles
Blocking access to the fire structure
Immediate area of involvement
Give three reasons for ventilation, according to IFSTA.
Life safety Speed of fire attack Fire spread control Reduction of flashover/backdraft potential Property conservation