WLE week 2 Flashcards

1
Q

the 2 objectives of grounding is to _________ the time it takes to trip a circuit and to _________ the current flow across the linemans body

A

minimize. limit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

every job does not have to start with a “tailboard” or safety briefing, according to osha true or false?

A

false

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

in order to properly ground a line, there is a 5 step process what is the first step?

A

idtcg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

in order to properly ground a line, there is a 5 step process what is the 5th step?

A

idtcg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

in order to properly ground a line, there is a 5 step process what is the 3rd step?

A

idtcg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

before grounds are applied, the lineworker must treat a conductor as if it is energized? true or false

A

true

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

before grounds are applied, the lineworker must treat a conductor as if it is energized and he/she must observe the?

A

minimum approach distance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

which method of testing the conductor is not a viable method and should be avoided?

A

buzzing method (fuzzing)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

cleaning the conductor before you ground it, provides a_______-__________ path for _________ to flow, because dirt, oxidation and corrosion increase resistance?

A

low resistance. current

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

the system neutral must be grounded at least _______ times per mile?

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

a “TGR” is a what?

A

Temporary grounding rod

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

the deeper the TGR is placed in the ground, the higher the resistance will be true or false

A

false

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

static wires on transmission structures, can consist of which two conductors?

A

fiber optic . steel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

which grounding source is accepted by some companies and frowned upon by others?

A

anchor rod

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

from the two grounding methods we discussed which is considered the best method?

A

EPZ

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

EPZ stands for?

A

Equipotential zone grounding

17
Q

EPZ does what?

A

keeps lineman safe

18
Q

the golden rule of grounding, states that the conductor is attached to first and then the ground source and when removing the grounds, you take the ground off first then the conductor true or false?

A

false

19
Q

minimum size size for grounding cable is

A

2 AWG

20
Q

the sheath on the outside of the grounding cable provides ___________ electrical protection?

A

no

21
Q

when inspecting your grounds, you are looking for missing pieces, loose connections and severe _________ and ___________ ?

A

cuts and scrapes

22
Q

what must be done to a grounding cable that has experienced fault current?

A

removed and tested

23
Q

where would your ground source be on a 3 wire distribution system?

A

ground rod

24
Q

according to the book, which term means uninterrupted flow of current?

A

continuity

25
Q

where would your ground source be on a 4 wire distribution system?

A

neutral

26
Q

OSHA requires a lineman to wait at least 5 min before grounding which piece of equipment?

A

capacitor bank

27
Q

a single ground connected to the supply conductor, or the phase that is being worked on is reffered to as?

A

personal ground

28
Q

a grounding spike clamp is not used as a protective ground?

A

true

29
Q

how do you establish EPZ for underground?

A

EPZ mat

30
Q

insulated protective cap is also known as?

A

dummy cap or a dead end cap

31
Q

with underground systems ________ and _______ are critical

A

tagging and identification

32
Q

when working underground what is the critical first step?

A

cable identification

33
Q

after grounding the end of the cable not being worked on, what must you install at the worksite?

A

EPZ mat

34
Q

osha was founded in ?

A

1970

35
Q

osha states that every job should begin with?

A

job briefing

36
Q

protective grounds must be installed to protect?

A

each employee

37
Q

reasons for grounding?

A

protect the employee and protect the system