Wiring Schematics And Circuit Testing Flashcards
On a wiring diagram, S110 with a “.8 BRN/BLK” means _______.
Splice of a brown with black stripe, wire size is 0.8 mm² (18gauge AWG)
Where is connector C250 located?
Under the dash
I’ll switch is illustrated and schematics are _____.
Shown in their normal position
When testing a relay using an ohmmeter, which two terminals should be touched to measure the coil resistance?
86 and 85
Technician A says that a good Leroy should measure between 60 and 100 ohms across the coil terminals. Technician B says that 0L should be displayed on an ohmmeter when touching terminals 30 and 87. Technician is correct?
Both
Which relay terminal is the normally close terminal?
87a
Technician A says that there is often more than one circuit being protected by each fuse. Technician B says that more than one circuit often shares a single ground connector. Which technician is correct?
Both
Two technicians are discussing finding a short to ground using a test light. Technician A says that the test light, connected in place of the fuse, will light when the circuit that has the short is disconnected. Technician B says that the test light should be connected to the positive and negative terminals on the battery during this test. Who is correct?
Neither
A short circuit can be located using a ______.
Test light
Gauss gauge
Tone generator
For an electrical device to operate, it must have ______.
Power and ground