WHAT ARE THE OSP'S FOR THIS MODALITY??? Flashcards
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
LVDC #1 OF 3:
207 BLUE BUTTON BOX?
X2
- CURRENT BUTTON = PRESS “DC CONTINUOUS
- REVERSE POLARITY
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
LVDC #2 OF 3:
SPONGE BOB BOX??
X2
- SWITCH BUTTON SET TO “NORMAL”
- SWITCH BUTTON SET TO “REVERSE POLARITY”
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
LVDC #3 OF 3:
ME 200 BLACK BOX??
X5
- CURRENT BUTTON = SET TO—— DIRECT
- FUNCTION BUTTON = SET TO—-AUTO
- METER BUTTON = SET TO B
- POLARITY BUTTON = SET TO +
- REVERSE POLARITY
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
HVDC #1 OF 3:
FORTE 200 COMBO???
OR
HVDC #2 OF 3:
LEGEND MACHINE???
***BOTH MACHINES ARE EXACTLY THE SAME!!
X5
- CHANNEL = 2
- POLARITY DOT = +
- PAD SWITCHING RATE (CYCLE TIME) =CONTINUOUS
- RAMP SETTING = 1
- PADS OR PROBE = CHOOSE PADS
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
HVDC #3 OF 3:
INTELECT 700 (LITTLE RED BUTTON)?
X4
- PRESS BUTTON = “VOLTAGE MODE”
- SET BOTH SUBRHEOSTATS = 100%
- SET FUNCTION BUTTON TO = CONTINUOUS
- POLARITY BUTTON = SET TO +
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
AC – SINE WAVE CURRENT
– W/ BLACK BOX –1 OF 3
“PULSE”
X3
- SET CURRENT BUTTON = PULSE
- SET FUNCTION BUTTON = PULSE FREQUENCY
- METER = B
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
AC – SINE WAVE CURRENT
– W/ BLACK BOX– 2 OF 3
“SURGE”
X3
- SET CURRENT BUTTON TO = PULSE
- SET FUNCTION BUTTON TO = SURGE
- METER = B
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
AC – SINE WAVE CURRENT
– W/ BLACK BOX –3 OF 3
“FORADIC”
X3
- CURRENT BUTTON SET TO = FORADIC (A)
- SET FUNCTION BUTTON TO = TETANIZE
- METER = A (MUST)
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
AC – SQUARE WAVE CURRENT – 1 OF 2
207A (BLUE BUTTON MACHINE)
X1
- CHOOSE “NARROW” (ACUTE) OR “WIDE” (CHRONIC)
***IF REHAB, THEN CHOOSE “WIDE” AND “SURGE” BUTTONS.
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
AC – SQUARE WAVE CURRENT – 2 OF 2
AC – FORTE 200 COMBO VIA “VMS” BUTTON
X4
- CHANNEL = 1
- RAMP = 1 SECOND
- MODE = SINGLE
- CYCLE TIME = CONTINUOUS
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
IFC – 1 OF 3
ME 220 (THE BLUE PLATE)
X 4
- BIPOLAR BUTTON = OFF
- 7 SECOND SWEEP = ON (OFF IF YOU PICK #4
- AMP. MOD BUTTON = CHOOSE “LIGHT ON” IF ACUTE OR “LIGHT OFF” IF CHRONIC
- IF YOU WANT TO PICK YOUR OWN NUMBER, PRESS THE “SINGE FREQUENCY SELECT” BUTTON AND PICK A SINGLE NUMBER IN THE BLACK “SINGLE BEAT FREQUENCY SELECTOR” BUTTON
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
IFC – 2 OF 3
LSII/2 (THE GREY BOX)
X3
- SWEEP BUTTON = ON
- VECTOR BUTTON = ON (ACUTE) OR OFF (CHRONIC)
- PREMOD = OFF
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
IFC – 3 OF 3
INTELECT 775 (BIG RED BUTTON)
X4
- CARRIER FREQUENCY BUTTON = 4,000 HZ
- INTENSITY BALANCE BUTTON = “BALANCE”
- PICK “QUAD POLAR BUTTON” IF CHRONIC
OR PICK “QUAD POLAR W/SCAN IF ACUTE - SET “SWEEP MODE BUTTON” TO “CONSTANT”
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
RUSSIAN STIM – 1 OF 3
LSI/2 (THE GREY BOX)
X1
- CHOOSE EITHER “10/10” FOR EDEMA OR CHOOSE
“10/50” FOR MUSCLE STIMULATION REHAB
“WHAT ARE THE OSP’S FOR THIS MODALITY???”
RUSSIAN STIM – 2 OF 3 AND 3 OF 3
THE LEGEND
FORTE 200 COMBO
X5
- CHOOSE CHANNEL = 1
- RAMP = 1 SECOND
- CYCLE TIME = CHOOSE 10/10 FOR EDEMA OR
10/50 FOR MUSCLE REHAB STIM - MODE = SINGLE
- DUTY CYCLE = 50%