Week 5: Oxygen Systems Flashcards
What is the most common colour of an aviation breathing oxygen?
Green
When servicing an oxygen system why is it important to use tools and wear clothing that is clean from petroleum products?
Pure oxygen supports combustion
What indicates that the relief valve has been activated if an oxygen cylinder has been over pressurized?
Green blowout disc
What is an indication of sever lack of oxygen at high altitudes?
Blue lips and fingernails(15000ft)
What is a symptom of lack of proper oxygen?
Sleepiness
What maintenance must be done on oxygen cylinders ever so many years to ensure they are still safe to use?
Hydrostatic testin
What is most severe outcome of lack of proper oxygen?
Unconsciousness (25000ft)
When are oxygen cylinders considered empty?
Below 50psi
When servicing an oxygen bottle on an aircraft what should be referenced in order to fill the bottle to the proper pressure?
Service placard or the temperature compensation chart
In general what pressure are gaseous oxygen cylinders rated to?
1800-1850psi
What should be done if the gaseous oxygen system is left empty for a long period of time?
Purge system
What should be used to check for leaks in a gaseous oxygen system?
Special leak testing solution
Aircraft oxygen systems keep cabin air pressure at what regardless of altitude?
8000ft
Small and medium aircraft designed without pressurization use what?
Supplemental Oxygen
Newer cylinders are made of what?
Al shell wrapped with Kevlar
Steel bottles are hydrostatically tested every how many years?
5 years
Composite bottles are hydrostatically tested every how many years?
3 years
Manufactured date and certification number are stamped where?
Cylinder neck
What are the 2 groups of oxygen systems?
Continuous and Demand flow
What are the 2 types of regulators for demand flow systems?
Diluted and Pressure
High pressure lines are made of what and how many psi?
Steel, 450psi
Low pressure lines are made of what and how many psi?
Aluminum, less than 450psi
What can be used with a pressure relief valve or on its own to relieve the system of excess pressure due to overfilling or high temperature?
Frangible/rupture disc
Oxygen valves should be open and filled how?
Slowly