Week 5 Definitions Flashcards

1
Q

Concealed

A

Rendered inaccessible by the structure or finish of the building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Continuous duty

A

Operation at a substantially constant load for an indefinitely long time

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Continuous load

A

A load where the maximum current is expected to continue for 3 hours or more

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Demand factor

A

The ratio of the maximum demand of a system, or part of a system, to the total connected load of a system or the part of the system under consideration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Dry location

A

A location not normally subject to dampness or wetness. A location classified as dry may be temporarily subject to dampness or wetness, as in the case of a building under construction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Dusttight

A

Enclosures constructed so that dust will not enter under specified test conditions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Enclosed

A

Surrounded by a case, housing, fence, or wall(s) that prevents persons from accidentally contacting energized parts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Guarded

A

Covered, shielded, fenced, enclosed, or otherwise protected by means of suitable covers, casings, barriers, rails, screens, mats, or platforms to remove the likelihood of approach or contact by persons or objects to a point of danger

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Enclosure

A

The case or housing of apparatus, or the fence of walls surrounding an installation to prevent personnel from accidentally contacting energized parts or to protect the equipment from physical damage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Energized

A

Electrically connected to, or is, a source of voltage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Explosion proof equipment

A

Equipment enclosed in a case that is capable of withstanding an explosion of a specified gas or vapor that might occur within it, that is capable of preventing the ignition of a specified gas or vapor surrounding the enclosure by sparks, flashes, or explosion of the gas or vapor within, and that operates at such an external temperature that a surrounding flammable atmosphere will not be ignited

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Exposed (as applied to wiring methods)

A

On or attached to the surface or behind panels designed to allow access

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

In sight from (within sight from)

A

Equipment that is visible and not more than 15 m (50 ft) distant from other equipment is in sight from that other equipment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Isolated (as applied to location)

A

Not readily accessible to persons unless special means for access are used

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Lighting outlet

A

An outlet intended for the direct connection of a lampholder or luminaire.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Live parts

A

Energized conductive components

17
Q

Luminaire

A

A complete lighting unit consisting of a light source such as a lamp or lamps, together with the parts designed to position the light source and connect it to the power supply. It may also include parts to protect the light source or the ballast or to distribute the light. A lampholder itself is not a ________.

18
Q

Multi-outlet assembly

A

A surface, flush, or freestanding assemblage with a raceway and fittings or other enclosure provided with one or more receptacles, for the purpose of supplying power to utilization equipment

19
Q

Rainproof

A

Constructed, protected or treated so as to prevent rain from interfering with the successful operation of the apparatus under specified test conditions.

20
Q

Raintight

A

Constructed or protected so that exposure to a beating rain will not result in the entrance of water under specified test conditions

21
Q

Readily accessible

A

Capable of being reached quickly for operation, renewal, or inspections without requiring those to whom ready access is requisite to take actions such as to use tools (other than keys), to climb over or under, to remove obstacles, or to resort to portable ladders, and so forth