Week 1 Flashcards
T or F
In high rise office buildings built before before 1945 did not use core construction techniques.
True
For high rise office buildings: which of the following required fire towers?
A- built before 1945
B- built between 1945-1968
C- built after 1968
B- build between 1945-1968
In a high rise office building: when operating the manual fire pumps, if you forget to close the bypass, what percentage loss can you expect on a 6” riser? 8” riser?
6” riser loss of 45%
8” riser loss of 25%
(6+4+5=15)(8+2+5=15)
In a high rise office building, the SAE group will require at least one unit for every # floors to be covered?
1 unit for every 5 floors
At a fire in a high rise office building, a supply of how many cylinders shall be maintained at the forward staging area?
20 cylinders
Where is the forward triage area established at a fire in a high rise office?
A the floor below the forward staging area
How many engines and how many trucks shall be at the forward staging area at a fire in a high rise office building?
3 engine and 2 trucks
The verbal button can be used if it is within # blocks of the firehouse.
Within 2 blocks for verbal
T or f
At the completion of. Each drill, the life saving TRAINING rope shall be removed from the carrying case and stored in a dark colored plastic bag in the company office
True
How much can the LSR shrink over time?
8-10ft
How much strength (in %) can the LSR lose when wet?
10-15%
To operate as a SSL does the officer need to be trained? How many members need to be trained?
The Officer and at least 3 trained members to operate as a SSL
To operate as a decon engine does the officer need to be trained? How many ff’s?
The Officer and at least 3 trained members to operate as a decon engine.
If a portable generator is used to power an exhaust fan, the ideal length of the electrical cord should be _#_ft or less?
50ft or less
T or F
When visible smoke is seen emanating through the exterior of the building (high rise office) you transmit a 10-76.
False, 10-76 second alarm when fire or smoke is seen emanating through the exterior of the building
At a fire in a high rise office building, all horizontal ventilation tactics shall be controlled, communicated, and coordinated by who?
The IC
High rise office buildings require a manual fire pump, make the correct match:
1938 building code. buildings over 300ft
1968 building code. Buildings over 600ft
1938 building code buildings over 250ft
1968 building code buildings over 300ft
Put the following in the correct order for the high-rise strategic operating plan: 1-determine the fire floor 2-control evacuation 3-confine and extinguish fire 4-verify the fire floor 5- gain control of building systems
1-determine the fire floor 2-verify the fire floor 3-control evacuation 4-gain control of building systems 5- confirm and extinguish the fire
How long and when do you operate the portable generators? During this time how long do you operate the lights???
Run generator for 15min weekly and during the time run the lights for 5 min