Weck test Flashcards
According to the high rise operations manual, book 100, chapter 3, base shall be at least how many feet from the building and not in proximity to the command post
200’
according to the high rise operations manual, book 100, ch 2, at high-rise incident a minimum of how many members comprise the initial fire attack team and ascend to the reported floor
four
according to the high rise operations manual, book 100, ch 3, when a water supply is established via the stairwell, who is responsible for providing a supply line to the entrance of the stairwell
Base
according to the high rise operations manual, book 100, ch 2, which company establishes lobby control
the second in company
according to the high rise operations manual, book 100, ch 2, who shall initiate accountability and tactical worksheet
(f-666)
incident commander
*according to the high rise operations manual, book 100, ch 1, where is the rapid intervention company normally located during a high rise emergency
staging
*according to the high rise operations manual, book 100, ch 1, which unit is responsible for coordinating the transportation of equipment via the stairwells
ground support
according to the high rise operations manual, book 100, ch 8 (water systems) dry standpipe outlets are located based on the requirement that every point within the structure must be reachable by a _____ stream of water from a nozzle attached to 100’ of hose
30’
*according to the high rise operations manual, book 100, ch 8 (water systems), orifice plates are a heavy gauge metal washer like device, which restricts the flow by restricting the size of the opening, thereby reducing the pressure when flowing. They are calibrated to supply _____ g.p.m at _____ p.s.i through 100’ of 1/2 hose with a 1” tip
200 gpm at 45 psi
*according to the high rise operations manual, book 100, ch 8 (water systems), buildings under construction that are _____ or more stories in height, shall be provided with not less than one standpipe for use during construction. Such standpipe shall be installed when the progress of construction is not more than _____ feet in height above grade, and shall be provided with a 2 1/2 outlet on each floor
six / 50
according to the high rise operations manual, book 100, ch 9 (salvage operations), damage to a structure and its contents are usually caused by heat, smoke and water. The main focus in salvage operations is the control of
water
*according to the high rise operations manual, book 100, ch 7 (elevators), the requirements for operation of elevators under fire and emergency conditions are provided by
title 24 of the California administrartive code
*according to the high rise operations manual, book 100, ch 7 (elevators), the code requires a building to have all the following except
smoke detectors installed adjacent to the elevators at each landing, usually in a vestibule, on all floors
*according to the high rise operations manual, book 100, ch 7 (elevators), the code requires phase I (recall phase) capability on automatic elevators having a total travel of
> 50’ or >25’ if new after October 6, 1975
according to the high rise operations manual, book 100, ch 7 (elevators), the lobby level “ emergency service “ switch is normally in the _____ position and when it is turned to the _____ position, all elevators in the bank controlled by the switch will be recalled to the lobby floor and remain there with their doors open
off / on
*according to the high rise operations manual, book 100, ch 8 (water systems), dry standpipe risers are, depending on building height, 4” to 6” diameter pipe and must flow _____ g.p.m per riser
500
*according to the high rise operations manual, book 100, ch 8 (water systems), dry standpipe outlets are located based on the requirements that every point within the structure must be reachable by a _____ stream of water from a nozzle attached to 100’ of hose
30’
*according to the high rise operations manual, book 100, ch ch 10 “ built-in systems”, high rise building communication systems provide public address communication to elevator car, elevator vestibules, corridors, stairways, rooms with an occupancy load of _____, and every dwelling unit in a hotel or apartment
> or = to 50