Warnings Flashcards

0
Q

BAT DISCH

and activated warning gong

A
  1. DC VOLTS, GEN AMPS and BAT AMPS - CHECK
  2. Electrical consumption - Reduce to save battery
  3. LAND ASA PRACTICABLE
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

BAT TEMP

and activated warning gong

A
  1. BAT MASTR sw. -“OFF”
  2. “LAND ASAP”
  3. Engine shutdown
  4. Visual inspection of battery
    If no overheating singn
  5. Start-up
  6. BAT MSTR sw -OFF
  7. LAND ASA PRACTICABLE
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

FIRE

and activated warning bell

A
  1. “OEI” flight condition
  2. “Respective EMER OFF sw - Open guard, press, release”
    Engine cut off, ACTIVE illuminate / F VALVE CL on cad
  3. “Affected engine. - Ident”
  4. ” Single eng emer shutdown”

If warning off
5. “LAND ASAP”

If warning ON
5. “LAND IMMEDIATELY”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

LIMIT

and warning GONG

A

One of the limits is exceeded:
Tq, TOT, N1, MM, OEI (30” or 2’) TOP time limit
Reduce the respective parameter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

LOW FUEL 1 and / or 2

+ warning GONG

A
  1. Fuel qty. - Check
    If positive
  2. Both fuel XFER pump sw. - Check ON
  3. Both fuel XFER pump cb. - Check IN

If LOW FUEL remain ON

  1. Air cond
  2. Bleed Air. - switch off ( if OAT>5c)
  3. “LAND within 10min”

WARNING: LOW FUEL overrules the fuel qty indication

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

ROTOR RPM
Low: Nro 97% or less. - Steady light / Intermitent low tone 800hz
High: Nro >106%. - Flashing light / Warning GONG
> 112%. - Flashing light / Continuous high tone 2400hz

A
  1. ” Rotor RPM indicator. - Check “
  2. ” Collective lever. - Adjust as necessary

If in addition Nro 10% to keep N2 and RPM matched

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

XMSN
OIL P

And warning GONG
and both XMSN OIL P caution on CAD

A

” LAND ASAP “

Reduce pwr as much as possible
Vy in level flight
MGB dry run > 25 min

Minimum. 0.5 bar
Continuous. 0.5 - 7.8 bar
Caution range 7.8 - 10 bar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly