Ventilation Flashcards

1
Q

Stairshafts in high rise buildings constructed after ___ are required to employ a stairshaft ventilation system.

A

1974

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Fan must provide not less than ____ while maintaining a positive pressure of not over ___ on interior doors

A

50 cubic feet per minute / 25 lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Pre-60 has _____ windows

A

openable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Post-60 has ___

A

tempered glass on at least two sides of the building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Post-60 Tempered glass location

A

at corners, and at 50 foot intervals or less

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Post-74 has ____

A

tempered glass on four sides of the building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Post 74 Tempered glass location

A

at corners and at 50 foot intervals or less

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Tempered glass windows are identified by ___

A

3 inch luminous or reflective decals in a lower corner which indicated for For FD use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Post 1996 “Uniform building code”

A

Requirement of smoke control systems in high rise buildings eliminated the requirement of installation of tempered glass

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Prior to breaking windows….

A

radio notification shall be made indication the need and intention to break glass and the specific side of the building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Natural air flow within building stairshafts is virtually static in buildings up to ___

A

25 stories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Buildings over 25 stories will naturally flow

A

minimal amounts of air in an upward direction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Natural vertical air currents of ____, can be created by simply opening a door at the bottom and roof levels of a stair shaft

A

3 to 6 mph

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

High rise buildings constructed after ____ are required to employ an _____

A

1974 / emergency smoke control system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

3 components of an emergency smoke control system

A

Pressurized stairshaft, mechanical smoke removal system, tempered glass or openable windows

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Positive pressure ventilation using blowers should be placed

A

4 to 6 feet back from doorway and angled back at least 5 degrees

17
Q

Placing fans in a ___ shape is more effective than placing them in series

A

V shape

18
Q

Cross ventilation operations are effective up to

A

25 floors

19
Q

Additionally the pressure generated by a fire (_____) will force smoke through these openings and may contaminate other floors or stairshafts within the building.

A

up to three times atmospheric pressure

20
Q

Windows:

Post –1960 – Tempered glass on at least ____ of the building. (At corners, and at 50-foot intervals or less.)

A

two sides

21
Q

Windows:

Post-1974 – Tempered glass on ____ of the building. (At corners, and at 50-foot intervals or less.)

A

four sides

22
Q

Tempered glass windows are identified by ____ luminous or reflective decals in a lower corner which indicate they are “_____ .”

A

3-inch / For Fire Department Use

23
Q

___ – Requirement of _____ (Uniform Building Code) in high rise buildings has eliminated the requirement of the installation of tempered glass.

A

Post 1996 / Smoke Control Systems

24
Q

However, the natural air flow within building stairshafts is virtually static in buildings up to ____. Buildings over ____ will naturally flow minimal amounts of air in an upward direction.

A

25 stories

25
Q

Therefore, when required, ventilation efforts directed at removing contaminants in these stairshafts must be augmented by ____ means other than utilizing natural air flow only.

A

mechanical

26
Q

Natural vertical air currents of ___, that flow upward in stairshafts, can be created by simply opening a door at the bottom and roof levels of a stairshaft.

A

three to six mph

27
Q

Water turbine blowers produce significantly less noise and will provide more than_____ that a like-sized gasoline powered blower. Water turbine blowers can be requested through MFC.

A

twice the cubic feet of air per minute

28
Q

Portable blowers should be placed _____ from the doorway and angled back at least ___. This maximizes the flow through the fan shroud and air entrainment around the fan shroud as it reaches the door. Placing fans in a _____ than placing them is series.

A

4 feet to 6 feet back / 5 degrees / V-shape is more effective

29
Q

The preceding cross ventilation operations are effective up to ___ in a high-rise building.

A

25 floors

30
Q

If it is necessary to cross ventilate floors above the ___, it may be necessary to utilize an ____ in the pressurized stairshaft to supply additional pressurized air to the floor to be ventilated

A

25th floor / additional blower