Noise intensity is measured in ____.
Decibels
The fall protection threshold is __ feet.
6’
The four ladder duty ratings are ?
Type IAA (375lb) Type 1 (250lb) Type 2 (225lb) Type 3 (200lb)
Any chemical on the jobsite is required to have a(n) ____, which contains data about safe use of the chemical.
SDS (Safety Data Sheet)
Solid State Devices can be damaged or destroyed by a static discharge as little as ___ V.
10V
In 1977, ____ was created to bring together OEM’s, designers, installers, and distributers to standardize the industry.
BICSI
What are the two types of Security Systems?
- ) Access Control Systems
2. ) Surveillance Systems
A(n) ____ is a network of hardwired or wireless video monitors that transmits sound and video, usually for large groups of people located in a common area.
Audio-Visual System.
What are the two basic cable types?
- ) Copper
2. ) Fiber-optic
A(n) ____ is a device that connects telecom devices to form a wireless network.
Wireless Access Point (WAP)
WAP’s are easily installed with Cat ___ or better.
5e
What factors are considered when choosing cable paths?
- ) Physical Layout
- ) Capacity
- ) Installation Environment
- ) Support System
110 Blocks are preferred by manufacturers because they have lower ____ and are more ____.
Lower Noise and More Compact.
A 110 type cross-connect can be arranged for use with either ____ or ____.
Jumper Wires or Patch Cords.
Insulation Displacement with a punchdown tool makes terminating faster and provides ____ and ____ results.
Consistent and Repeatable
All test equipment must be used per the ____ from the ____.
Written Instructions from the OEM.
____ is the reduction of power in any type of signal.
Attenuation.
____ is a type of interference caused by signals from adjacent circuits.
Crosstalk
____ is the measure of signal interference as measured at the far end of the cable.
Far End Crosstalk (FEXT)
Attenuation to crosstalk ratio (ACR) is the ratio of ____ to ____.
Attenuation to Near End Crosstalk (NEXT)
A ____ is an analytical tool that can be created by certain types of test instruments and is used to certify all the fibers in a specific cable.
Cable Loss Report
The higher the category of copper cabling, the ____ the twisting of the conductors is.
Tighter.
A tightly twisted wire pair ensures that both wires experience the exact same ____ and ____ of external noise.
Shape and Volume
Twisted pair conductors are called the ____ and ____.
Tip and Ring.
In normal four pair cables, the white of the twisted pair is usually the ____.
Tip.
Substituting a higher rated cable will cost ____ than a specified lower-rated cable.
More.
What is the maximum length of a horizontal cabling run?
100 Meters (about 300’)
Does the maximum length of a cabling run include patchcords at the end?
Yes.