Utility Flashcards
Propane has a vapor density of ____ and will ____ in air.
A. 1.40, rise
B. 1.56, sink
C. 0.50, rise
D. 1, mix
1.56, sink
pg 25
If the detection equipment shows a CO reading of ___ppm or above, the occupancy shall be immediately evacuated and crews should retreat from the structure and don their SCBA.
A. 10
B. 25
C. 35
D. 50
35
pg 29
The continuous movement of free electrons through the conductors of a circuit is called a ____ and is measured in _____.
A. Current, voltage
B. Flow path, amps
C. Current, amps
D. Flow path, voltage
Current, amps
pg 31
Electrical burns must be treated at what type of medical center?
A. Level I trauma center
B. Burn Center
C. Free-standing Emergency Department
D. Level II trauma center
Burn Center
pg 43
The top line of numbers on a utility pole indicates which number?
A. GPS coordinates
B. Map grid number
C. Pole number
D. Approximate voltage
Map grid number
pg 36
During a natural gas related emergency, the curb box shut off may be located by finding which indicators on or near the street?
A. Green painted lines or utility company discs
B. Orange painted lines or utility company placard
C. Red painted lines or utility company placard
D. Yellow painted lines or utility company discs
Yellow painted lines or utility company discs
pg 23
When given an order to take care of or secure utilities, what is this referring to?
A. Water
B. Water and electric
C. Electric
D. Electric and gas
Electric and gas
pg 5
Miss Utility can be reached by dialing the following number in VA?
A. 411
B. 611
C. 811
D. 911
811
pg 7
The ignition temperature for natural gas is?
A. 1000F
B. 1200F
C. 1350F
D. 1500F
1200
pg 8
Which of the following is correct regarding pipeline marking systems?
A. Markers show the exact location of the pipeline
B. Pipelines follow a straight line between two markers
C. Signs on the markers do not indicate the commodity transported
D. Markers do not indicate how deep the pipeline is buried or how many lines are in the area
Markers do not indicate how deep the pipeline is buried or how many lines are in the area
pg 10
For a reported outside gas leak, a break in what diameter line should the incident be upgraded to a hazardous materials response?
A. 0.5 inch
B. 0.75 inch
C. 1 inch
D. 2 inch
2 inch
pg 14
When gas meters are located on the interior, members should be looking for a vent pipe on the outside wall. The vent pipe will likely have a cover screen to keep water, insects, and debris out of the gas relief piping. This piping vent pipe must be withing how many feet of the vent on the inside of the wall?
A. 10 feet
B. 8 feet
C. 5 feet
D. 3 feet
5 ft
pg 22
What is considered a momentary outage?
A. An electrical outage lasting two minutes or less
B. An electrical outage that lasts for more than three minutes
C. An electrical outage lasting three minutes or less
D. An electrical outage that lasts for more than two minutes
An electrical outage lasting two minutes or less
pg 2
APWA color code Red is for which of the following?
A. Gas, oil, steam, petroleum, or gaseous materials
B. Communications, alarm, or signal lines, cable, or conduit
C. Electric, cable, conduit, and lighting cable
D. Proposes excavation.
Electric, cable, conduit, and lighting cable
pg 6
____is a simple hydrocarbon consisting of carbon and hydrogen.
A. Polyvinyl chloride
B. Propane
C. Methane
D. Coal
Methane
pg 8