What temperature do cryogenic systems operate
-150°C (302°F) or less
General rule of thumb for Condensor size vs Evaporator
1.25% larger
Define a secondary refrigerant
a refrigerant that does not change state within the system (ie. chilled water)
Define Saturation Temperature
when the product is the same temperature as the refrigerant
What is the purpose of the oil separator
to separate 90% of the oil from the refrigerant
According to “some guy”, where is the filter drier located on a cascade system
on the discharge line of the compressor (removed TQ question)
Autocascade has 3 _______ _______ refrigerants that ________ with one compressor
Autocascade has 3 blended zeotropic refrigerants that fractionate with one compressor
On startup, low temp refrigerants act as _____ and drive discharge pressure ___
On startup, low temp refrigerants act as Non-condensables and drive discharge pressure up
Autocascade is ___ to pull down, Cascade is ___ to pull down
slow, fast. 3 hours vs 30 min
When checking pressures on an autocascade system, it is important to use a ___ (long/short) hose
short
when a leak on an auto cascade system is detected, you can top up refrigerant (true/false)?
false, refrigerant is a blended mixture that’s a bigger secret than Colonel Sanders’ 11 herbs an spices. Aside from knowing the proper mixture it is next to impossible to know how much and what refrigerant leaked out
on ultra low systems, it is important to achieve ___ microns blank off
200
Define Rebound
the Re-expansion of remaining refrigerant in a Recip compressor before a pressure differential is achieved to allow suction gas to enter
formula to convert Inch-Mercury to PSIA
14.7 - (InMerc/2.04)
formula for compression ratio
discharge pressure/ suction pressure IN ABSOLUTE