A typical setting for the high-pressure cut-out control on a recovery unit used for evacuating refrigerant from a low-pressure chiller is

A

10psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A charged low pressure refrigeration system can be efficiently leak-checked by

A

raising system pressure by heating with circulated hot water or heating blankets

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The existence of air in a low pressure system causes

A

high head pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which safety precaution should be adhered to for low pressure systems?

A

All of the above.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Refrigerant-11 (R-11) at 14.7 psia, will boil at about

A

74.5 F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When there is excessive moisture collecting in the purge unit of a low pressure refrigeration system, this indicates that

A

the condenser or chiller barrel tubes are leaking.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

ASHRAE Standard 15-1994 requires equipment room refrigerant sensors for what safety group classification?

A

All safety groups

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When recharging a refrigeration system with R-11, what vapor pressure is necessary in the shells before charging with liquid?

A

16.9 inch Hg vacuum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

After reaching the required recovery vacuum on a chiller, you should

A

wait for at least a few minutes to see if the system pressure rises, indicating there is still refrigerant in liquid form or in the oil.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

A hydrostatic tube test kit is used to

A

Determine if the tubes leak

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When charging a chiller, refrigerant vapor is introduced into the system before charging with liquid refrigerant. This is because

A

liquid charged into a deep vacuum will cause the refrigerant to boil and may lower temperatures enough to freeze the water in the tubes.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When evacuating a system, the use of too large a vacuum pump can cause

A

trapped water to freeze.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

On a low pressure chiller with an open-type compressor, the _________ is/are very susceptible to leaks.

A

Shaft seal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What steps may be taken to prevent air accumulation into an idle low-pressure refrigeration system?

A

System pressure should be maintained slightly above atmospheric pressure.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Commercial and industrial process refrigeration systems must be repaired when the leak rate exceeds ______ percent of the charge per year.

A

30%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When recovering vapor from a low pressure refrigeration system,

A

the system water pumps, the recovery compressor, and the recovery condenser water should all be on.

17
Q

Where does refrigerant go after it leaves the purge unit of a low pressure centrifugal system?

A

The evaporator

18
Q

The purge unit takes its suction from the

A

Top of the condenser

19
Q

Which of the following repairs would ALWAYS be considered a “major” repair unde EPA’s regulations?

A

Replacement of an evaporator coil.

20
Q

Charging liquid refrigerant into a refrigeration system when it is under a 29-inch Hg vacuum can cause the

A

system water to freeze.

21
Q

Charging liquid refrigerant into a refrigeration system when it is under a 29-inch Hg vacuum can cause the

A

system water to freeze.

22
Q

According to the EPA there is approximately ________ of refrigerant vapor left in an average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed.

23
Q

An oil sample should be taken when

A

there has been a compressor burnout.

24
Q

Both CFC-11 and HCFC-123 chillers require purge units because

A

the system operates below atmospheric pressure.

25
Q

Under EPA regulations, _________ is used to pressurize a low-pressure chiller for the purpose of opening the system for a non-major repair.

A

warming the refrigerant