Type 1 Flashcards

1
Q

which hydrocarbon is approved for retrofit into existing household refri?

a) HC R-600a, 2 ounces or less
b) blended HC R-441a
c) HC R-290
d) Hydrocarbons are not approved for retrofit applications

A

d) Hydrocarbons are not approved for retrofit applications

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

low loss fitting

a) they can be either manually closed or automatically closed
b) they are used to connect
c) they are used to connect
d) they eliminate oil loss during recovery

A

a) they can be either manually closed or automatically closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

which does NOT meet Type I

a) an mvac-like system that hold 3 pounds of R-12
b) water cooler
c) food freezer
d) dehumidifier

A

a) an mvac-like system that hold 3 pounds of R-12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

maximum normal charge to use system dependent recovery equipment

a) 5 pounds
b) 10 pounds
c) 15 pounds
d) 50 pounds

A

c) 15 pounds

because it’s system dependent recovery equipment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

refrigerant in a recovery cylinder is suspected to be contaiminated

a) take a pressure reading of the cylinder
b) weight cylinder
c) discard refrigerant
d) dilute the refrigerant with virgin refrigerant

A

a) take a pressure reading of the cylinder

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

when R-410a is recovered from an appliance

a) can be mixed
b) can be mixed
c) need not be recovered
d) should be recovered into a recovery vessel that is clearly marked to ensure that mixing of refrigerants doe not occur

A

d) should be recovered into a recovery vessel that is clearly marked to ensure that mixing of refrigerants doe not occu

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

a standard vacuum pump designed specifically for evacuation and dehydration

a) be used alone as self-contained recovery device
b) never be used as a recovery device in combination with a pressurized container
c) be used alone as substitue for any recovery device
d) be used alone as a system-dependent

A

b) never be used as a recovery device in combination with a pressurized container

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

when is it essntial to take measures to help release trapped refri from the compressore oil during refri recovery

a) when using self-contained recovery device
b) when using system-depenent acitve recovery devices
c) when using passive recovery devices on small appliance with non-operating compressors
d) when the refri system has a low side leak

A

c) when using passive recovery devices on small appliance with non-operating compressors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

which condition can cause excessive pressure on the high side of a self-contained(active) recovery device?

a) when the thermal expansion valve is stuck open
b) when the capacity of the recovery tank is larger than the charge size of the system
c) when there is a large volume of non-condensable gas in the refri being recovered
d) when the system is set for no subcooling

A

c) when there is a large volume of non-condensable gas in the refri being recovered

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

monitoring 80% fill level in a recovery tank

a) superheat when a capillary tube is present
b) refri scale or tank internal float device
c) refri temperature measurement
d) refri pressure measurement

A

b) refri scale or tank internal float device

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

how many access valve…..

a) 2 valves
b) only 1 access valve on the low side
c) only 1 access valve on the high side
d) 2 valves

A

c) only 1 access valve on the high side

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

what should the nitrogen tank always be equipped with

a) regulator
b) float sensor
c) red top
d) hand valve

A

regulator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

refri decompose into at hight temp

a) hudrazine
b) phosgene
c) helium
d) tetraethyl

A

b) phosgene

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

large leak, no breathing apparatus

a) use butyl
b) use leak detector
c) vacate and naturally ventilate the ares
d) make sure the unit

A

c) vacate and naturally ventilate the ares

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

refri leak can cause suffocation

a) smell strong and make breathing difficult
b) are lighter than air
c) are heavier than air and displace oxygen
d) sting the nose

A

are heavier than air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

new household refri factory charged, EXCEPT

a) R-290
b) R-450a
c) R-600a
d) R-404a

A

b) R-450a

17
Q

a passive system-dependent recovery process for a small appliance

a) sitll use a pump to recoverrefri
b) must use a pressure relief device
c) captures refri in
d) can only perform on a system with an operating compressor

A

d) can only perform on a system with an operating compressor

18
Q

recovering refri into a non-pressurized container with an inoperative compressor

a) helpful to heat or strike the compressor with a rubber mallet
b) only necessary to recover as much
c) not necessary to recover
d) necessary to chase

A

a) helpful to heat or strike the compressor with a rubber mallet

19
Q

when installing any type of access fitting onto a sealed system

a) the fitting should be leak tested before proceeding the recovery
b) it’s not necessary to leak test an access fitting
c) the fitting need not be leak tested
d) the system must be pressure/….

A

a) the fitting should be leak tested before proceeding the recovery

20
Q

after installing and opening a piecing access valve, the recovery procedure cannot begin if the system is at what pressure?

a) 75 psig
b) 50 psig
c) 30 psig
d) 0 psig

A

d) 0 psig

21
Q

why would solderless type piercint valve not remain installed on refri system after completion of repairs

a) they are too expensive
b) they tend to leak overtime
c) they restrict refri flow
d) they tend to trap lubricant

A

b) they tend to leak overtime

22
Q

the nitrogen

a) must be recovered
b) may be vented to the ambient air
c) should be returned to the cylinder
d) should only be used if mixe/….

A

b) may be vented to the ambient air

23
Q

required when attaching a gauge set to check system pressures

a) release a small amount of refri to check for contamination
b) have manual or self-sealing valves on the end of the gauge set hosed to minimize any release of refri
c) recover refri and recharge to spe
d) use hoses that are 3 feet or longer

A

b) have manual or self-sealing valves on the end of the gauge set hosed to minimize any release of refri

24
Q

what must be done to the refri that is vented off the top when filling a charging cylinder

a) the refri need not be recovered
b) the refri must be recovered only if it’s CFC or HCFC
c) the refri must be recovered if it’s CFC, HCFC, HFC
d) the refri must be reclaimed or incinerated

A

c) the refri must be recovered if it’s CFC, HCFC, HFC

25
Q

why watch for signs of contamination in the oil

a) contaminants cannot be removed from the refri
b) the system will have to be flushed if contaminants are present
c) the contaminants will eat away at the recovery equipment
d) the contaminant will plug up the recovery equipment

A

a) contaminants cannot be removed from the refri

26
Q

recommended safe work practices when recovering refri

a) wear safety eyewear and butyl-lined gloves when connecting/disconnecting hoses
b) wear a respirator when working
c) wear cotton glove
d) ventilation is only necessary

A

a) wear safety eyewear and butyl-lined gloves when connecting/disconnecting hoses

27
Q

approved refri for new household

a) R-600a
b) R-1234yf
c) R-1233zd
d) R-170

A

a) R-600a

28
Q

permissible to use passive recovery device for recovery CFCs, HCFs, HFCs

a) centrifugal air conditioner
b) reciprocating liquid chiller
c) a single compressor, large commercial walk-in freezer
d) a domestic refri

A

d) a domestic refri

29
Q

which condition requires accessing both sides when using system-dependent recovery process

a) when there is a leak
b) when the compressor operates normally
c) when the compressor only runs at half speed
d) when the compressor does not run

A

d) when the compressor does not run

30
Q

stabilize to room temp before taking a pressure reading

a) to prevent safety valves from purging refri
b) it’s quick method
c) comparisons to a pressure-temp chart only valid if both the temp and stable and known
d) a temp reading alone is enough to determine refri quality

A

c) comparisons to a pressure-temp chart only valid if both the temp and stable and known

31
Q

the system dependent recovery process

a) never needs the use of a pump
b) must use a pressure relief device
c) recover refri in a non-pressurzied
d) can only be performed on a system with an operating compressor

A

d) can only be performed on a system with an operating compressor