Truck Company Operations Flashcards
What is the side to side slope capacity for the truck itself?
0-5 Full capacity
5.1-8 Half capacity
>8 Zero Capacity
What is the side to side slope of the ground?
10 Full capacity
13 half capacity
>13 Zero capacity
What is aerial capacity front to rear of the truck itself?
0-5 full
5.1-8 half
>8 Zero
What is the aerial capacity front to rear of the ground slope?
7 Full
10 Half
>10 Zero
What is the minimum safe distance for a aerial device around wires?
10 ft
What does SLICE-RS stand for?
Size up
locate fire
identify flow path
Cool from a safe distance
extinguish
rescue
salvage
Where should a turntable be placed?
in line with the target
How should a turntable be positioned based on smoke conditions?
Slightly upwind
Positioning decisions should prioritize
life safety of civilians and firefighters
What is setback?
Horizontal distance between the building and the turntable
What setback is required for a tower to position at or below grade?
30ft
What is scrub area?
portion of a building that can be reached by the tip of the aerial
Outriggers should never be placed over
manhole covers
storm sewer boxes
underground vaults curbs not supported by a curb
What is the size of the collapse zone
1.5 times the height of the building
Lateral
side to side movement