1
Q
Pre-Formalities
A
- Receive AWC from issuing person(s).
- Ensure all staff, tools and equipment are provided.
- Liaise with track operatives.
- Book in with CSS.
- Book adequate protection from
Line Controller - Call Asset Control Centre and provide them with scope of work, location and estimated finish time.
- Inform signaller of area of work and request control of the site.
2
Q
Pre Rerail
A
- Prove meter on known source.
- Remove R and Q fuse and adjacent R fuses.
- Make a note of track connections and disconnect.
3
Q
After Re-Rail
A
- Check continuity of IBJs on ohms.
- Replace R fuses of adjacent tracks.
Ballast Leakage Test:
- Extraneous Voltage Test
- <0.5v if above lift Q1. If still above escalate to DSIM. - Induced Loop Test
- Apply dead short at T-End
- <0.2v if above lift Q1. If still above escalate to DSIM. - Reinstate R and Q fuse.
- Q1 - Earth test = 100v
- Q2 break test
- observe TR fully de-energise and 6 front contacts break. - Cap in section
- O/p of cap to earth = Track Volts
- Top links all on section - TR-GR if any (break Q1 on GR) and watch TR fully de-energise and 6 front contacts break.
- Relay energisation.
- Opposition
- V1 + V2 = V3 (Highest value of V1 or V2) - 1 ohm shunt track at extremities and mid, 1m over points.
- Re-gauge any equipment within the track.
4
Q
Post Formalities
A
- Clear up site.
- Ensure all staff and equipment are of site and give up protection with line controller.
- Give back control of site to Signaller/Control Room TO. Inform manger of completed works.
- Check all signals have cleared.
- Control movement of trains until proved to shunt.
- Clear AWC with ACC.