when the TL is used for ventilation purposes what tools must be placed in the bucket?
axe, halligan, power saw, 6’ hook and life saving rope
4.1.2
With members operating on an ISOLATED roof the pedestal man shall make certain the basket is not moved. What shall the pedestal man do if a life hazard should appear requiring movement of the boom?
pedestal man shall advise roof personnel PRIOR to moving the basket.
4.1.2
- when operating on a roof of questionable stability with hand tools or power saw full use of the personal harness and life saving rope shall be used to limit travel of operator of tool to a radius of no more than _____ feet.
- Rope shall be tied to a substantial part of the basket. Operator shall use what knot and how big should the loop be?
- 10 feet
- Bowline with 15’ loop
- 1.4
How is saw started and shut down when operating from the basket ?
Started in basket and then held outside the basket. It shall be kept outside until shut off. 4.3.1 b
What shall be done to prevent the saw from falling while operating from the basket?
a utility cord shall be attached to the handle of saw to prevent it from falling. Cord to be lashed to basket or held by back up man(4.3.1 G)
When using the saw from the basket to cut a peaked roof how big shall the cut be?
the size of the cut will depend on the reach of the operator. He shall never over extend himself.(4.3 note)
- When using basket to rescue and remove people which railing shall be used to be level with with window ledge or top railing of fire escape where person can easily step onto basket wihout the usual straddling?
- Which railing shall on basket shall be used to line up with window sill or top railing of fire escape to remove incapacitated or obese victims?
- Middle basket railing
2. Top rail
5. 1
To expedite placing basket at window, place apparatus parallel to the objective so which part of TL is in line with window or target, the turntable or basket?
the basket (5.1.4)
when many trips of the basket are required to remove a great number of occupants, safe removal need not necessitate delivery directly to the street level. Where time is crucial, occupants may be placed at lower levels of the fire building, an adjoining fire escape, an adjacent roof, or any other area of refuge.(true or false)
True (5.1.6)
Who may order the use of TL streams?
Only the officer in command of operations may order the use of TL streams
How shall TL stream be delivered when a fire building is heavily involved on several floors?
heavy stream delivery should generally start at the lowest level and work upward, effecting a quick knock down on the way up to top floor and/or cockloft area, in order to protect members in basket operating at the highest level.(6.2.2)
Where stability of the building is in doubt the basket shall be placed in a manner minimizing the effects of falling walls, etc. If possible at what distance shall the basket be placed from the building?
if possible, the basket should be placed at least the same distance horizontally from building as it will be vertically below the top of the wall.(6.2.3 F)
When a TL stream needs to be shut down the water is shut down where?
at the supply pumper(6.5.1)
can TL be moved without disconnecting lines?
Yes. when distance is short and sufficient slack is in the line, the TL may be moved without disconnecting lines if adequate manpower is available.(6.5.1)
What can be done if the intensity of the radiant heat is preventing the positioning of the TL?
Hand lines can create a protective water curtain, position apparatus, raise boom and swing it away from fire until water to TL arrives.(6.5.3)