T or F. All supports have a direct frame attachment to bypass the apparatus suspension and provide a rigid operating base.
True (2.1.1)
To eliminate any possibility of stabilizer support collapse brought about by loss of fluid from a cylinder, a mechanical lock is also provided at each jack and outrigger. What must be done to lock them?
Insert pins. (2.1.3)
If the apparatus is not level, which side should be lowered first?
The low side.(2.1.4)
T or F. The guide firefighter is to remain in position until the outrigger is fully lowered on the operator’s blind side.
True. (2.1.5)
What can be used to judge that an outrigger will clear all obstructions?
6ft hook
Who must personally verify the placement of all outriggers and jacks prior to raising the boom from the bedded position?
Any member operating the tower ladder (2.1.9)
What must be done if a member starts to set up a tower ladder for operation and then decides to abort the operation?
Properly place all outriggers and jacks up for operation OR return all outriggers and jacks to the pre-setup position. (2.1.10)
What is the floor area of the TL basket
15ft
When is the use of the platform control switch (deadman control) necessary?
Whenever a member or civilian enter or leave an elevated basket. (2.4.5)
If one of the 3 manually operated isolation valves for the hydraulic circuits (raise-lower, etc.) should malfunction for any reason, what can be done?
The isolation valve can be closed leaving the other systems operable. (2.4.5.2)
What two ways can a member escape from the basket?
Fixed telescoping ladder mounted on the boom sections or by LSR in conjunction with personal harness. (2.61.)
Boom rotation permits water coverage of ?
360 degrees
What are the inlets for water on a TL?
3” x 3” gated Siamese on the left side and a 4 1/2 inlet on the right side.
Whom should perform delicate operations, if visibility permits, the pedestal man or the basket man?
The pedestal man. (2.8.4)
When should the ht be utilized in basket operations?
1) When basket man operating alone for venting
2) Search purposes as a means of cooderinating operations with interior forces
3) As a means of communication should he leave basket for any reason, such as search or rescue
(2. 8.6)
When should the intercom be tested?
Daily check of apparatus and at intial stages of placing TL into operation
What are the four ways a member can be secured to operate in the basket?
1) wearing the installed safety belt
2) wearing life belt
3) Personal harness secured to substantial part of basket
4) Loop formed in LSR, 1ft in diameter, around a substantial part of the basket using a bowline, then hooking life belt or personal harness onto this loop.
(2. 9.3)
At what angle should the front end of the apparatus be parked at to increase the scrub area?
15 degrees
When may it be more advantageous to park perpendicular to the building?
Where the stability of the ground is doubtful, such as vacant lots or unpaved areas. (3.1.6)
When should the TL turntable be placed in line with an alley?
At one or two family private dwellings or any structure with an alleyway between the fire building and an exposure. (3.1.8)
If members leave basket for search or roof operations, the LCC at the pedestal should not move boom unless________?
Members are advised of his intention and they in turn give approval, or a visible life hazard should occur. (3.1.11 J)
A properly positioned TL provides wall coverage from grade level or below, up to a maximum basket floor elevation of ____ at the maximum ____degree angle?
70’ , 75’ (3.2.1)
A basket while touching a point 32 feet horizontally from center of turntable can reach a basket floor elevation of?
65’ (3.2.2)
If a TL scrub area covers the front of a building 60’ high by 50’ wide, how much frontage will it cover of the lower 3 floors of the building?
100’
If the center of the turntable is 32’ from the building wall and the cab is angled out at 15degrees, it will have a scrub area of approximately ?
7750’
The basket can reach points how many feet below grade?
10 feet
Tor F. TL may be placed on sidewalk only partially to reach upper levels or gain better vantage points.
False. Can also be placed fully. (3.2.6)
When the center of the of the turntable is 25ft from the building, will there be sufficient room for the basket to be dropped below the horizontal?
Yes.
What is the ideal horizontal distance from objectives?
32’. ( as opposed to aerial ladders which is 25’ to 35’ for a good climbing angle
Where should the TL basket be lined up with when positioned at fires?
Apparatus is placed parallel to the objective and the basket in line with the target. (3.3.1)