Time Intervals Flashcards
Vacuum Box - Minimum duration of each vacuum-testing exam
5 seconds 650: 8.6.8
NDE - Minimum time an examiner should be in a darkened area
prior to using a black light for MT & PT exams
5 minutes
V: T-676.4.b
& T-777.2.b
NDE - Final interpretation of a PT exam after application of
developer (time range)
10-60
minutes
V: T-676.1
Testing - Minimum time to let oil to penetrate when performing
a diesel oil test of shell-to-bottom weld
4 hour
650: 7.2.4.1.d
& 653: 12.1.6.1
Testing - Minimum duration for a tank hydrotest to be held at
full height
24 hour 653: 12.3.1
NDE - Max Calibrating Interval - Permanent magnet MT Yoke
1 day V: T-762(a)
Intervals - Maximum Interval - Routine In-Service inspection
1 month 653: 6.3.1.2
CP - Maximum Interval - Routine check of CP impressed
current sources
2 months 651: 11.3.2.2
NDE - Max Calibrating Interval - RT densitometer
90 days V: T-262.1
Reconstruction - Maximum allowed age of last thickness
readings, used to design a reconstructed tank
180 days 653: 8.4.1
Weld Qualification – Maximum Time - Welder or operator
maintains qualifications for a welding process without
using that process
6 months
IX: QW-322.
1.
NDE - Max Calibrating Interval - Electromagnetic MT Yoke
1 year V: T-762(a)
CP - Maximum Interval - Detailed check of CP impressed
current facilities
1 year 651: 11.3.2.3
CP - Maximum Interval - CP surveys (field potential
measurements)
1 year 651: 11.3.1.2
NDE - Minimum Time - To keep RT’s acquired during tank
repairs and reconstructions
1 year 653: 13.2.3.d