TexasFlashcardsTostudyfortheTXExam
Inspection committee members serve _____ years
a. 2 b. 3 c. 4 d. 6
d
A Real Estate Inspector must have _____ hours of continuing education to renew his/her license each year. a. 2 b. 4 c. 6 d. 8
d
_______ Members serve on the Inspection Committee. a. 5 b. 6 c. 9 d. 12
c
A professional Real Estate inspector must have _____ hours of continuing education each year?
a. 4 b. 8 c. 12 d. 16
d
Before a Professional Inspector may sponsor an Apprentice, the Profession must have completed at least ____ inspections as a Professional Inspector
a. 150 b. 175 c. 200 d. 300
c
Payments for claims from the recovery fund arising from the same transaction shall not exceed _____ regardless of the number of claimants. a. $5,000.00
b. $10,000.00 c. $12,500.00 d. $30,000.00
c
The minimum size for a crawl space is ____ x _____ inches. a. 18x20 b. 16x24 c. 18x24 d. 22x30
c
The minimum live load for a balcony is _____ pounds. a. 60 b. 80 c. 150 d. 200
a
What type of window is hinged on one side only?
a. Hooper b. Double hung c. Casement d. Barrier
c
An inspector is required to operate any _____ valves of the plumbing system. a. Exposed b. Main c. Outdoor hose bib d. Branch
c
An inspector shall inspect the _____ for leaks a. Gas supply line b. A/C coolant suction line c. A/C coolant supply line d. Crawl space water supply pipes
d
A stud on a load bearing wall may be notched up to _____ percent. a. 25 b. 33 c. 40 d. 60
a
The number that is used to divide square footage by when calculating attic or crawl space ventilation is?
a. 75 b. 100 c. 125 d. 150
d
Switches for a spa or hot tub shall be located at least _____ feet from the inside walls of the spa or hot tub.
a. 2 b. 3 c. 5 d. 6
c
The minimum pitch for a terra cotta or clay tile roof is ______ a. 2/12 b. 2½/12 c. 3/12 d. 4/12
b
_____ inches X ______ inches is the minimum dimension for a egress window in a sleeping room.
a. 20 – 24 b. 24 – 30 c. 22 – 30 d. 24 – 36
c
_____ inches is the maximum distance that a window sill can be located from the floor in a bedroom.
a. 24 b. 30 c. 40 d. 44
d
The maximum length of a dryer vent is _____ feet. a. 10 b. 15 c. 20 d. 25
d
The maximum length of a flexible gas line (excluding a range or a dryer) is _____. a. 2 b. 3 c. 6 d. 10
b
The minimum clearance of an electric service wire over a walkway is _____ feet. a. 8 b. 10 c. 12 d. 18
b
Romex must be supported at least every ____ feet in an attic a. 2 b. 2 ½ c. 3 ½ d. 4 ½
d
The minimum size for an attic access having a clear height over 30 inches is _____ X _____
a. 18 x 24 inches b. 22 x 30 inches c. 24 x 30 inches d. 24 x 36 inches
b
The minimum length for a cord to a garbage disposal is _____.
a. 12 inches b. 18 inches c. 24 inches d. 36 inches
b
The maximum length for a cord to a dishwasher is ____.
a. 18 inches b. 36 inches c. 48 inches d. 72 inches
c
Pull and plug floor lamps have cords that are _____ feet long a. 3 b. 4 c. 6 d. 8
c
Hallways of ____ feet or more in length shall have at least one receptacle outlet. a. 8 b. 10 c. 12 d. 14
b
The minimum size (AWG) circuit conductor for a 20 amp circuit is ____ gauge copper. a. 14 b. 12 c. 10 d. 8
b
The minimum branch circuit for a range is a rating of _____ amps. a. 20 b. 30 c. 40 d. 50
c
The minimum height that a flue vent can terminate above the roof is ______.
a. 6 inches b. 1 foot c. 18 inches d. 2 feet
d
The minimum clearance for an electrical wire over a swimming pool is _____ feet.
a. 12 b. 14 c. 16 d. 22
d
Woodwork or other combustibles should not be placed within _____ inches of a fireplace opening.
a. 2 b. 3 c. 4 d. 6
d
The bottom of a vent terminal and an air intake shall be located at least _____ inches above grade.
a. 12 b. 9 c. 6 d. 3
a
A minimum of two ____ amp rated branch circuits are to be provided to serve receptacles located in the kitchen, pantry, and breakfast area.
a. 15 b. 20 c. 30 d. 40
b
Range and dryer connections labeled for a metal appliance connection may not exceed _____ feet.
a. 3 b. 6 c. 8 d. 10
b
The minimum hearth extension on the side of a fireplace with a 6 square foot opening and a firebox depth of 24 inches is _____ inches.
a. 3 b. 6 c. 8 d. 12
d
The maximum distance that mechanical equipment can be located from an attic access is ____ feet.
a. 10 b. 15 c. 20 d. 25
c
The minimum clearance for lighting over a swimming pool is _____ feet.
a. 10 b. 12 c. 14 d. 18
b
Surface mounted fluorescent fixtures shall be installed on the wall above the door or on the ceiling, provided there is a minimum clearance of _____ inches between the fixture and the nearest point of a storage space.
a. 2 b. 3 c. 6 d. 8
c
The minimum distance for a breaker box from a swimming pool is _____ feet.
a. 2 b. 3 c. 5 d. 6
c
12 gauge aluminum wires should be connected to a _____ amp breaker
a. 15 b. 20 c. 25 d. 30
a
The maximum distance between handrails on a stairway is _____ inches.
a. 0 b. 2 c. 4 d. 6
b
The minimum thickness for a solid garage door to a living area is ____ inches.
a. 1 1/8 b. 1 ¼ c. 1 3/8 d. 1 ½
c
You cannot take return air from a _____. a. Bedroom b. Hallway c. Dining room d. Kitchen or bathroom
Romex must be stapled a maximum of _____ inches from the wall outlet and then every 4.5 feet.
a. 3 b. 6 c. 9 d. 12
d
The minimum stairway tread is _____ inches.
a. 7.75 b. 8.25 c. 9.5 d. 10
d
The minimum width of a stairway with two handrails is _____.
a. 24 inches b. 28 inches c. 30 inches d. 36 inches
b
A gas line is permitted to run inside a ______.
a. Clothes chute b. Combustible air duct c. Return air vent d. Supply air vent
b
Recessed incandescent fixtures with a completely enclosed bulb can be installed in the wall or ceiling, provided there is a minimum clearance of _____ inches between the fixture and the nearest point of storage space. a. 3 b. 4 c. 6 d. 12
c
An inspector should operate the motor on an evaporative cooler to see if _____.
a. It vibrates b. It is one or two speed c. It is functioning in normal operating mode d. All of the above
b