Texas SOP Flashcards
Inspections shall be delivered within ___ days of receipt of payment, unless otherwise agreed in writing.
2
Inspection report shall include the ____ and ____ of each inspector, as well as the ____ and ____ professional inspectors.
Name and license number
Supervising and sponsoring
The TREC adopted the property inspection report form ____ for the inspection of substantially complete ___ to ___ family residential properties.
REI 7-6
1- 4
An inspector is not required to enter a crawl space where headroom is less than ___ inches or access opening is less than ___ wide by ___ high.
18”
24” wide by 18” high
The inspector is not required to enter attics or unfinished spaces where access openings are less than ___ inches by ___ inches or headroom is less than ___ inches.
22”x30”
30”
On decks higher than ___ inches above grade, spacings between balusters, spindles, or rails that allow the passage of an object greater than __ inches are prohibited.
30”
4”
Inspectors are not required to enter any area where headroom is less than __” or access opening is less than ___” wide by ___” high.
18”
24” by 18”
Brick and masonry siding must be ___ inches above finished grade.
6”
Weep holes should be at least ___ in width, no more than ___ apart, and located immediately above the ___.
3/16”
33”
Flashing
The foundation area square footage should be divided by ___ to determine the square footage of ventilation area required for a crawl space.
150
Crawl space ventilation openings should be within ___ feet of each corner.
3’
Interior areas of monolithic concrete slab foundations must be at least ___ inches thick.
3-1/2”
Cracks that extend through the middle of several ____ and are ___ inch or more in width should be noted, and could be signs of ____ issues.
Bricks
1/4”
foundation
The door between the residence and an attached garage should be a ___ ___ door or ___ ___ ___ ___ door at least ___ inches thick, or other wise a ___ ___ ___ ___ door.
Solid wood door
Solid honeycomb core steel door
1-3/8”
20 minute fire rated
Windows less than ___ inches from the finished floor and greater than ___ inches from finished grade require ___ protection.
24”
72”
Fall protection
Spacing between intermediate balusters, spindles, rails, stairways, guards, and railings shall not allow the passage of an object greater than ___ inches in diameter, or less than ___ inches for guard rail balusters or spindles located on the open side of staircase treads.
4”
4-3/8”
250 volt overcurrent devices and multi-wire branch circuits should have ___ ___.
trip ties
Receptacles within ___ feet of the outside edge of a sink, shower, or bath tub should be ___ ___.
6’
GFCI protected
Receptacles less than ___ feet from the finished floor should be tamper resistant.
5-1/2’ (66”)
Smoke alarms are required outside each ___ ___ in the immediate vicinity of the ___ ___ and in the ___ ___ of each ___ of the dwelling.
sleeping area
sleeping rooms
living space
story (floor)
Carbon monoxide alarms are required outside each separate ___ ___ in the immediate vicinity of the ___ ___ if a ___ ___ appliance is installed in the dwelling or an attached ___ with an opening to the dwelling exists.
sleeping area
sleeping rooms
fuel fired
garage