Tests Flashcards
Fire test
EICAS messages
L R ENG FIRE
APU FIRE
L R JET OVHT
After 10 seconds:
HYD SOV 1 2 OPEN
L R ENG SOV OPEN
APU SOV OPEN
Fire test
Fail position
Single chime Master caution lights illuminated EICAS MESSAGES: L R FIRE FAIL APU FIRE FAIL L R JET OVHT FAIL
Fire test
Firex monitor test
EICAS MESSAGES:
L R SQUIB 1 x2
L R SQUIB 2 x2
Duct monitor selector switch test position
AURALS: Triple chime, "Bleed Air Duct" EICAS: L R 10th DUCT (red) L R 14th DUCT (red) ANTI-ICE DUCT (red) DUCT TEST OK (red) Lights: Master warning, Duct Fail (red) on L R 10 & 14 Stage switch, Duct Fail on wing OVHT switch
DUCT MONITOR switch on Loop A
DUCT MON LOOP A (white) on EICAS
DUCT MONITOR switch on Loop B
DUCT MON LOOP B (white) on EICAS
Stall test
CONT IGNITION (white) on EICAS
Stick shakers-on
Stick pusher-on
STALL lights illuminated x2
GPWS TEST
GPWS FAIL message (white) WIND SHEAR FAIL message (white) TERRAIN FAIL message (white) G/S switch/light illuminated AURAL: "Glideslope, Whoop Whoop, Pull Up" "Windshear, windshear, windshear, terrain, terrain, whoop, whoop, pull up"
MLG Bay Overheat Test
OVHT position
EICAS MESSAGES:
MLG OVHT (red)
“Gear Bay Overheat” aural
MLG Bay overheat test
Fail position
MLG OVHT FAIL (Amber) on EICAS
Overspeed test switch
Aural clacker sounds
TCAS TEST
White TEST next to VSI
VSI indicator active/Traffic RED flashes
Threat symbols (4) displayed
“TCAS System Test Okay” aural
Fire test
Warn position
Fire bell
Triple chime
“Jet pipe overheat” aural
Master warning x2
LH RH ENG FIRE PUSH lights (red) illuminated
APU FIRE PUSH light (red) illuminated
Engine (green) BOTTLE/ARMED/PUSH/TO/DISCH light illuminated x2
APU (green) BOTTLE ARMED TO PUSH TO DISCH light illuminated
Anti-skid test
A/SKID INBD (Amber)
A/SDIK OUTB (Amber)
Fuel check valve test
L R BOOST PUMP INOP (Amber)
R FUEL LO PRESS (Amber)