Tests Flashcards

0
Q

Which section contains code for ferrous materials, such as welding rods

A

ASME Section II

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

Chemical an petroleum refinery piping is ASME ___?

A

B31.3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which code contains specifications for the construction of heating boilers

A

ASME Section IV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The initials PFI abbreviation

A

The pipe fabrication institute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The pressure reducing value on a hot water boiler is normally preset to

A

12 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The safety relief value on a residential hot water boiler is normally preset at

A

30 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A LTHW boiler is limited to

A

250F to 160psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The PRV maintains minimum pressure on the upper most floor at

A

4psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which organization is responsible for the code for pressure piping in North America

A

ANSI/ASME

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The initials ASME are

A

The American society of mechanical engineers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The drain valve on a residential hot water boiler should not be smaller the 1”NPS

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

A zone valve is designed to

A

Start and stop the flow of water to a circuit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What will the wild loop minimize or prevent

A

The potential for deadheading at the pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

A LTHW boiler is usually ___ rated

A

Net

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

A LTHW boiler is governed by ASME code section ___

A

IV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

A conventional cast iron hot water boiler is limited to

A

30 psig

16
Q

A HTHW boiler is governed by ASME code section ___

A

I

17
Q

A HTHW boiler is usually ___ rated

A

Gross

18
Q

A HTHW boiler is usually rated in

A

EDR or MDH

19
Q

The EDR for water and steam is

A

150 & 240

20
Q

Two variables you’ll find on a pump curve are

A

Head and flow

21
Q

What does ODT stand for

A

Outside design temp