Test Flashcards
The VariAx Clavicle Hook plate is another SOMA designed implant from Stryker. SOMA is a new 3D modeling and analytics system designed to create implants that have optimized fit and function.
T/F
TRUE
If a combination of non-locking and locking screws are used in the diaphyseal region of an AxSos3 plate, begin with _________ Screws prior to the placement of any __________ screws.
Non-Locking; Locking
Which depth is not offered in the Clavicle hook plates?
A: 12mm
B: 16mm
C: 18mm
D: 20mm
C: 18mm
The VariAx Clavicle Hook plate uses the same instruments and screws as
VariAx Elbow
Utilizing SpeedGuide has reduced the cone of angulation for VariAx locking screws from +/-15 to +/-10.
T/F
False
The most common treatment for a non-displaced proximal humeral fracture is:
Nonsurgical, Conservative Treatment
Select some indications for the VariAx Clavicle Hook Plate:
A: Lateral clavicle fractures
B: Medical clavicle fractures
C: Nonunions & mal-unions
D: Dislocations of the AC joint
A, C, D
How many locking screw hole options are available at the proximal end of the T2 PHN?
4
All the superior plates in the VariAx Clavicle system have:
A medial to lateral Bow in the AP view
The VariAx SpeedGuide combines which 3 instruments into one?
Drill, Drill Guide, Depth Gauge
You can use _______ screws with the VariAx clavicle plates.
2.7mm & 3.5mm
There are dedicated superior mid-shaft plates that are designed with enhanced strength to bridge fracture comminution areas.
T/F
True
The ReUnion HA Fracture System is cementless (press fit).
T/F
False
What are the 4 muscles of the rotator cuff?
Supraspinatus; Infraspinatus; Teres Minor; Subscapularis
Which one of Stryker Hemiarthroplasty products is appropriate for a Proximal Humeral fracture?
ReUnion HA Fracture System
When measuring the depth with SpeedGuide, drill until the far cortex is felt, add the thickness of the far cortex to the measurement on the scale, and then…
Drill the far cortex
Plate choies is a key feature of the VariAx Clavicle system. There are _____ Plates of different lengths and anatomic shapes from which to choose.
35
How many locking screw hole options are there in the metaphysical portion of the AxSos Proximal Humeral Plate?
7
Just like the VariAx system, AxSos 3 has variable angle locking in the shaft of the plates.
T/F
False
Which one of these products is not appropriate for a Proximal Humeral fracture?
A: T2 PHN
B: Proximal Humeral Plate
C: T2 Standard Humeral Nail
C
Which one of these is not a design feature of the AxSos Proximal Humeral Plate?
A: Anatomically designed left and right plate options
B: Low 2mm plate profile
C: Locking and Non-locking screws
B
Just like all other SmartLock technology, the VariAx clavicle has softer Grade 2 Ti plates and harder Grade 5 Ti screws.
T/F
False
What does SOMA stand for?
Stryker Orthopedics Modeling and Analytics
The initial position of the SpeedGuide can be verified when the tip is securely engaged in the plate and the drill is in ______ mode.
Lock