What is the purpose of the NEC

A

Protection of persons ans property from the hazards of electricity use
90.1 (a)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What does the westerberg explosion test vessel measure

A

Maximum experimental safe gap (MESG)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Who has the responsibility for enforcemet and interpretations of the rules in the code

A

Authority having jurisdiction

90.4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Class III location is hazardous because of the presence of easily ignitable ________

A

Fibers or Flyings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In 1937, class II locations were first defined and designated with which of the following groups

A

Group E, F, and G

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Which one of the following are generally involved in determining the extent of a hazardous location

A

All or any combination of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Ammonia

A

ANSI / ASHRAE 15 - 1994

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Class I loaction

A

Gas and Vapors

500.5(b)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Under the Zone System, Atmospheres containing acetylene, hydrogen, or flammable gas fall into which of the following groups

A

GroupIIC

505.6 (a)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

A common method of minimizing explosion hazards from ignition sources created by electrical wiring and equipment in hazardous (classified) locations is to _______

A

Locate as much or all of the equipment outside the classified location

500.5 (a) info note

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Effective ground-fault current path must _____

A

Facilitate overcurrent device operation

250.4 (a)(5)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The bonding required for a Class I location is required for all intervening raceways, fittings, boxes, enclosures, and so forth between the Class I location and the _____

A

point of grounding for the service equipment or separately derived system
501.30 (a)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The acceptable protection techniques in the NEC for use in the Division System are found where

A

Section 500.7

500.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Authorities having jurisdiction will base approvals on the use of ______ electrical equipment and materials

A

Listed

90.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Flameproof equipment provides the same practiacl protection as ______ equipment because it provides reasonable assurances that exhaust from an internal explosion will not ignite the atmosphere around the enclosure

A

explosionproof

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

______ and circuits are often installed in hazardous (classified) location because the energy available in these circuits of systems is incapable of causing ignition

A

Intrinsically safe systems

504.2

17
Q

Under the Division System what marks are required on equipment

A

Class, Division, and Material Classification Group

500.8(c)(1-4)

18
Q

in a Class I Division 1 location, a luminaire is required to be marked with the ________ of the lamp(s) for which it is identified

A

Maximum wattage

501.130 (a) (1)

19
Q

Which of the following wiring methods is not permitted in a Class I, Division 1 location

A

Nonmetallic sheathed cable

501.10 (a)(1)

20
Q

Type MI cable is permitted as a wiring method in Class I Division 1 location when used with _____

A

fittings listed for the location

501.10 (a)(1)(b)

21
Q

Which wiring method below is not permitted for use in a Class I Zone 1 location

A

Nonmetallic sheathed cable

505.15(b)(1)

22
Q

A multiwire branch ciruit is not permitted in a Class I location unless it meets which of the following requirements

A

The disconnect opens all ungrounded conductors of the circuit simultaneously
501.40 exc

23
Q

When unusual conditions exist in a hazadous location in a special occupancy covered by the NEC which of the following entities has the final responsibility for judgement and application of code rules

A

The authority having jurisdiction

90.4

24
Q

In a commercial minor repair garage service room where gaseous fuels are not transferred and which does not provide at least four (4) air changes per hour, what is the extent of the Class I Division 2 location

A

18” above the floor and 3’ horizontally from the edge of any such pit, belowgrade work area, or subfloor work area
511.3 (d)(1)(b)

25
Q

The power circuits supplying a hospital operating room that utilizes flammable anesthetizing agents are required _____ and shall be supplied from an isolated power system

A

To be ungrounded

517.61(a)(1)