Test 2 Flashcards

1
Q

To break a stuck nut loose you should use a

A

Box wrench

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Hammer drills are used for drilling holes in

A

Masonry and concrete

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What type of tool is used to trace a lost or mislabeled cable

A

Toner and amplifier probe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What do you coat steal fasteners with to prevent corrosion

A

Zinc

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Article 800 in the NEC coveres

A

Communication circuits

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

A balanced signal is transmitted on what type of cable

A

Twisted pair

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

An unbalanced signal is transmitted on what type of cable

A

Coaxial

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A twisted pair has a maximum run distance of

A

90 meters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The maximum pull force for unshielded twisted pair cable shall not exceed

A

25 lbs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

To improve conductor flexibility and durability use a

A

Stranded conductor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How do you start a cut in box

A

Horizontal in case you hit a stud

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What type of cable goes floor to floor

A

Riser

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Where can you use riser cable

A

Vertical and horizontal in non plenum spaces

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where can you use plenum cable

A

Anywhere

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Where can you use general purpose cable

A

Only horizontal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Can class 2 and 3 cables be used with class one cables

A

Yes when they are separated by a barrier

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

General purpose cable must be ________ and classified for specific use and purpose

A

Listed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

General purpose cable must be listed and ________ for specific use and purpose

A

Classified

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

The three parts of a coaxial cable

A

Braid
Conductor
Dielectric

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Three types of communication cable are

A

Twisted
Fiber
Coaxial

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is abandoned communication cable

A

Cable that is not terminated at the device or identified for future use with a tag

22
Q

The front edge of a box shall be no more than ________ from the finished surface of a Sheetrock wall.

A

6mm

1/4 in

23
Q

The three parts of a screwdriver are

A

Shank
Handle
Blade

24
Q

What is a plenum space

A

A compartment or chamber to which one or more air ducts are connected to form the air distribution system

Environmental air

25
What is a riser space
A vertical shaft where wire runs from floor to floor
26
How will modifying a UL listed box affect its listing
Negates the UL listing
27
A balun is a device designed to
Change a signal from balanced to unbalanced
28
Define AFF
Above finished floor
29
Why is it important to measure on center and AFF
More accurate and uniform
30
Which article covers fire alarm code
760
31
Article 760 covers?
Fire alarm code
32
What article covers communication circuits
800
33
Define green concrete
Concrete under 28 days old
34
What must you do to mount an anchor on concrete less than 7 days old
Have a site test from the manufacture
35
What is abandoned cable
Not terminated or listed for future use
36
What type of device must be installed on a fire rated wall
A fire rated device
37
Electrical/non electrical box must have what warning
Power limited side must state " for low voltage use only"
38
What is a bushing for
Protect wires from abrasions
39
What is bend radius
Specific degree of bend to prevent breakage
40
UTP
Unshielded twisted pair
41
Bend radio us for UTP
4 times outer diameter
42
Bend radius for multi pair
Not smaller than 10 times
43
Bend radius intra building
2 inches minimum
44
What is a cross over cable used for
Testing | Flexible durable and can connect devices
45
Fiber optic bend radius
15x
46
What is pull force for fiber optic cable
50 pounds
47
What is BiCi standard for
Communication wire | 2 90 degree bends per 100 feet of cable
48
Max run distance for coaxial
185 m
49
Max run distance for fiber
2km
50
Max run distance for coaxial
185 m
51
Max run distance for fiber
2km