Test 1 True/false Flashcards
Dry saturated steam is in a semi-gaseous state
True
An open feedwater heater vents gases to the atmosphere
True
Pressure on water does not change boiling point of the water
False
A dry pipe separator increases the quality of steam leaving a steam boiler
True
Try cocks are not effective above a steam pressure of 250 psi
True
An economizer isa heat exchanger that absorbs heat from the gases of combustion leaving the boiler
True
Superheating steam is imposible at low steam pressure
False
The boiling point of water is not effected by boiler pressure
False
Waterwalls permits greater heat absorption per cubic foot of furnace volume than refractory walls
True
A glove valve offers less resistance to flow than a gate valve does.
False
Is a plant has only one boiler an automatic non-return valve is not necessary.
True
The stop valve in a boiler feedwater line should have the pump discharge pressure on the top of the valve disk when the valve is closed.
False
A calorimeter measures excess air being used for combustion
False
Boiler tube dimension are based on the inside diameter of the tube
False
Absolute pressure is pressure below the atmospheric pressure
False