Test 1 Flashcards
FIVE major features or functions of quints are…
Pre-piped waterway on the aerial apparatus
Size if the water tank
Amount of supply and attack hose
Size of the fire pump
Array and length of ground ladders
FOUR factors that affect the choice of a type of aerial apparatus….
Length of reach
Most common tasks required of the device
Amount of equipment the apparatus needs to carry
Maneuverability
When the main aerial device cannot reach a portion of the building, what portable tool is typically used…
Pole Ladder
Water delivery systems
Discharge elevated master streams for fire attack from the aerial device
Aerial apparatus driver/ operators are regulated by…
State laws, City ordinances, department SOP’s
Identify the TRUE statement about lugging…
Lugging occurs when the engine is placed in a gear that is too high for a particular situation.
When entering an intersection, you should..
Make eye contact with other drivers at or entering the intersection.
When inspecting the front of the aerial apparatus, be sure to check the…
Windshield
When checking the automatic transmission fluid driver/ operators should perform a…
Hot check
Identify TWO aerial apparatus systems that are used for the extension of the aerial device…
Cable, Hydraulic
To provide electric power to multiple connections, aerial apparatus driver/operators should use..
Junction boxes
To provide electric power to multiple connections, aerial apparatus driver/ operators should use…
Junction Boxes
When working with hydraulic extrication tools, driver/operators should wear…
Safety gloves
Two main purposes of the operational inspection …
To review aerial device operation for the D/O
To ensure That the aerial device is in proper working condition
Four Pre-Service tests for aerial apparatus
Road tests
Certification tests
Hydrostatic tests
Acceptance tests
D/O will often perform..
Service tests
Testing the discharge pressure gauges and flow meter is important because if these devices are not working properly..
You could supply dangerously insufficient or excessive amounts of water
Perform vacuum test…
After engine speed check
Tracking engine performance over time requires data collected in the..
Fuel, oil, and mileage record
Steps to turning on apparatus
- Disconnect all auxiliary electrical and air sources
- Turn on apparatus’s battery/batteries
- Start the engine
- Observe the apparatus’s gauges
- Check seat, mirrors, and steering wheel
- Check that all crew members have fastened seatbelts
Three steps to making a right turn..
Move apparatus to right lane
Activate right turn signal
Check to see if the side street or road is clear
During relay pumping operations, the intake pressure relief valves are used…
To reduce the potential for damage to the pump or hose lines
When checking the hydraulic fluid level
Use a dipstick or sight gauge
Three stabilizer components are…
Pads, Deployment, hydraulics
To ensure safety at a highway scene…
Turn the front wheels away from the firefighters working the incident
The apparatus will remain stable as long as the:
Gravity circle does not extend outside the base of stability
One challenge of operating on a longitudinal grade is the:
Rungs of the aerial device will not be parallel to the ground.
The collapse zone is:
One and one half the building
When performing rescue operations, aerial D/O should position the aerial device..
Upwind and at the corner of the building
Three objectives aerial D/O should meet when determining proper distance between the intended target and the aerial apparatus…
Maximum stability
Best climbing angle
Adequate extension
When responding to a medical incident, D/O should preferably park:
Off the street
To reduce stress when an aerial apparatus must operate off an incline, the driver operator can:
Spot the turntable downhill from the point of operation