Technical Specifications Flashcards

1
Q

What are the required actions if SL’s are violated in Mode 1 or 2?

A

Restore compliance and be in mode 3 within 1 hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the required actions if SL’s are violated in Mode 3,4 or 5?

A

Restore compliance within 5 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the basis for SL?

A

Prevent overheating of the fuel and cladding, as well as possible cladding perforation.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What does LCO 3.0.1 state?

A

LCO shall be met in mode of applicability

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What does LCO 3.0.2 state?

A

Upon discovery of failure to meet an LCO the required actions shall be met

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What does LCO 3.0.3 state?

A

Mode 3 within 7 hours, Mode 4 within 13 hours, Mode 5 within 37 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What does LCO 3.0.4 state?

A

When LCO is not met, entry into a mode can of applicability can only be made if:

1) Associated actions permit continued operation
2) A risk assessment is performed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Does LCO 3.0.4 apply to 3.8.1.b

A

No - A risk assessment cannot be performed for the EDGs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What does LCO 3.0.5 state?

A

Equipment declared ions to comply with actions may be returned to service to demonstrate operability

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What does LCO 3.0.6 state?

A

Inoperability is not cascaded to support systems. SFD must be performed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What does LCO 3.0.7 state?

A

Physics testing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What does LCO 3.0.8 state?

A

A system is not declared inoperable due to an inoperable HELB barrier (i.e. AFW)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What does SR 3.0.1 state?

A

Failure to meet the SR shall be failure to meet the LCO

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What does SR 3.0.2 state?

A

Specified frequency is met if the surveillance is performed within 1.25 times the interval specified

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What does SR 3.0.3 state?

A

IF surveillance is not performed within specified frequency, then compliance to declare the LCO not met may be delayed 24 hours or the interval of the surveillance. A risk eval must be performed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What does SR 3.0.4 state?

A

SR must be met when entering a mode of applicability

17
Q

To apply 1.3 Completion Times, what conditions must be met?

A

1) Subsequent failure must exist concurrent with the first inoperability
2) Must remain inoperable after the first inoperability is resolved
3) Subsequent Train

18
Q

How does one apply 1.3 Completion Times?

A

More restrictive of:

Stated completion time from initial inoperable + 24 hours

Stated completion time from subsequent inoperable

19
Q

3.4.10 (PRZ Safety) What are the required actions if one Pressurizer Safety valve is inoperable?

A

15 minutes to restore valve to operable status

20
Q

3.4.4 (RCS Loops Mode 1&2). How many RCS loops must be Operable in mode 1 and 2?

A

Four RCS Loops - Heat Removal

21
Q

With no SI pumps capable of injection and only one CCP, what are the LTOP requirements? 3.4.12

A

1) Accumulators Isolated
2) One of the following
- Two PORVs in LTOP mode 435#
- One PORV in LTOP with RHR suction at <450#
- RCS depressurized and an RCS vent > 2” or single PORV blocked

22
Q

With no SI pump and both CCP capable of injection what is required for LTOP? 3.4.12

A

1) Accumulators Isolated
2) Two PORV in LTOP
3) RHR Suction Relief
4) RCS CL >140F

23
Q

What RCS CL temp is LTOP applicable?

A

U1 <266F U2 <299F