TB 195: The MSA G1 SCBA consists of ____ major components.
9
TB 195: A lack of movement by the user for ____ seconds will activate the PASS alarm consisting of the LED lights flashing red and the alarm increasing in stages until full alert at ____ seconds.
20 ; 30
TB 195: The MSA G1 air cylinder holds ____ cubic ft. of breathing air
66
TB 195: The cylinder weighs ____ lbs. is ____ inches high and ____ inches in diameter.
13.9 lbs ; 23.2 inches ; 6.3 inches
TB 195: Removal of the quick connection is accomplished by rotating the handwheel counterclockwise ____ and squeezing the quick connection while pulling away from the cylinder.
1/4
TB 195: The color bands located nearest the cylinder valve come in ____ colors.
5
red, blue, green, orange, yellow
TB 195: The two side handles are rated at ____ lbs static force and the top handles are rated at ____ lbs static force.
500 ; 1000
TB 195: The second stage regulator and storage clip is located on the ____ side of the waist belt.
left
TB 195: The adjustable swiveling lumbar pad has ____ settings so that the lumbar portion can be adjusted to the small of the users back to ensure the weight is carried on the hips.
three
TB 195: The air cylinder is secured to the carrier frame in ____ locations. The first is at the bottom of the SCBA bottle by a dovetail design. The second is by the stainless steel band with an integrated adjustment mechanism and band release at the top of the SCBA bottle. Also located on the harness are ____ speakers from which the audible alarms will sound.
2 ; 2
The Universal Air Connection (UAC) is a male fitting rated for ____ PSI located adjacent to the cylinder quick connection.
4,500
When air cylinder pressure is at ____PSI or ____ % of remaining air, a white LED light will illuminate the UAC fitting to assist with locating it for use.
1575 PSI ; 35%
The Universal Emergency Breathing Safety System (UEBSS) Y Block is a ____inch intermediate pressure hose with male and female quick connection fittings.
39 inch
The first stage regulator lowers the air cylinder’s high pressure to approximately ____ PSI, which is then supplied to the second stage regulator via an intermediate high pressure hose.
115 PSI
The pneumatic bell integrated into the low air warning alarm is located on the first stage regulator and emits an audible ring when the pressure reaches _____ or ____ % of the rated air cylinder pressure remaining.
1575 PSI ; 35 %
Once activated, the low air warning bell will operate until the air cylinder pressure reaches ____ before shutting off completely.
200 PSI
The second stage demand valve regulator supplies breathing air via a ____ inch intermediate pressure hose at over ____ of breathing air per minute to the user.
24 ; 120 liters
The regulator houses an electronic module which provides a HUD function and ____ microphone placement.
dual
The large red knob on the second stage regulator controls the adjustable bypass valve. when the bypass is turned _____ it provides a constant flow of breathing air at a maximum of _____ liters per minute.
counter clockwise ; 120
The bypass valve shut-off is the translucent and gray button on the regulator, which also houses a forward facing LED and air status indicator, which provides the following information:
____% - LED activates and flashes yellow
____% - LED changes from ____ to ____ and flashes at a faster rate.
50 ; 35
yellow ; red
The second stage regulator is attached to the facepiece in proper orientation by firmly pushing it into place with the red bypass knob on the ____.
right
The second stage regulator, including the speaker modules and Bluetooth connectivity (currently disabled for LAFD), is activated by a ____.
sharp inhale
The Heads-Up Display HUD transfers light through windows on the second stage regulator. The ____ side of the HUD provides air management information. The ____ side provides icons for battery status, and PASS status.
right ; left
When the Battery icon flashes ____, battery is low.