What are the TACW pump auto starts?
- Low disch # at
155# (U1)
145# (U2)
What are the TACW pump trips?
- Load Con
- Load Shed
- Overload/Overcurrent
What are the TACW Loads?
- Exciter Coolers
- Bus Duct Cooling
- H2 Coolers
- Stator Water Coolers
- Steam Packing Exhauster (U1)
- Gland Steam Condenser (U2)
Where are the TACW pumps powered from?
- 11/21 A
- 11/21 B
When do the TACW Inlet Valves to the Steam Packing Exhauster and Gland Steam Condenser (CMO-630/635) go closed??
- on an Extreme High Level
Where does TACW fit in on the condensate system?
- TACW supply and return lines tap into the Condensate System between the HWP discharge and the Excess Flow Line to the CST
What is TACW cooled by?
- CW in the TACW HX tubes
What does CMO-600 do for the TACW system?
- Its the TACW bypass valve and it can only be manually operated
What are the Auto action(s) that occur in the TACW Sys? (besides Pump auto start)?
- Steam Packing Exhauster and Gland Steam Condenser TACW Inlet valves close on an Extreme High Level
During a Startup when is the TACW sys placed in service?
- Placed in service prior to drawing vacuum and placing steam seals in service
Describe how makeup water is added to TACW System?
- Makeup water is supplied through a small bypass line around open cycle shutoff valve C-210, which is closed at this time.
Above what temperature must TACW be in “Closed Cycle”?
- TACW from Hotwell temps
> 95°F (U1) (> 104°F (U2)) must be in CLOSED CYCLE
With TACW in “Closed Cycle” is Cycle efficiency better or worse?
- Rejects heat to lake lowering cycle efficiency
With TACW in “Open Cycle” is Cycle efficiency better or worse?
- Increases cycle efficiency
What is TACW “Modified Open” cycle [Toad Cycle]?
- Open cycle with the TACW Hx
- Used to Reduce overall condensate temperatures
- Used up to 30% power to reduce overall condensate temperatures